4.Stopping the generating set
1
Remove the connectors of all
electric equipment from the
generating set panel.
WARNING
NEVER stop the engine with
electrical devices connected
and running.
2
Turn the combination switch to
the"stop"position,the
generator stops operation.
Wireless remote shutdown
(if applicable)
Press and hold the "OFF"button
for at least 0.3 seconds to stop
the generator.After the
generator stops,turn the
combination switch to the"stop"
position.
Note:When the control distance
is shortened or the indicator
light is on but the remote control
function is not available.
Wireless remote replace the
battery.Contact your local
dealer for more information.
One-button start-stop
(if applicable)
Press the start-stop button to
turn off the generator.After the
generator shutdown,turn the
combination switch to"stop"
position.
If the generator will not be
used for a long time,please
turn the combination switch to
the"off"position.After the
fuel in the carburetor oil cup to
runs out and the generator
automatically shuts down,turn
the knob to the "stop"position.
If the combination switch knob
is not turned to the "stop"
position,there is a risk of fuel
leakage.And the battery will
be undercharged after a long
time placed,resulting in failure
(to start the generator.
3((If applicable)
After the generator stops and
cools down,turn the fuel tank
cap ventilation knob to "OFF"
position.
22
WARNING