CAUTION
Allow the generating set to cool
for at least two minutes before
removing fuel cap when adding
fuel.
Loosen the fuel cap slowly to
relieve any pressure in the
tank.
5 Battery connection
(If applicable)
Remove the battery
maintenance cover,connect the
battery terminal to the motor
terminal,and reinstall the
maintenance cover.
6 Electrical devices
Disconnect all electrical devices
from the generating set and
switch off the AC circuit breaker
before start the engine.
The generating set may be hard
to start with electrical devices
connected.
The power of connected
electrical devices cannot exceed
the generating set max power,
specific power see parameter
sheet for reference.
7 Generating set grounding
The generating set must be
properly connected to an
appropriate ground.It helps
prevent electrical shock ifa
ground fault condition exists in
the generating set or in
connected electrical devices,
especially when the unit is
equipped with a wheel kit.
Proper grounding also helps
dissipate static electricity,which
often builds up in ungrounded
devices.
Electrical Shock
Failure to properly ground
the generating set can result
in electric shock.
A ground terminal has been
provided on the generating set.
15
DANGER