General information

5.1 General information on digital multimeter
5.1.1
The digital display 4 is a 4-digit LC display with a font size of 13 mm and
a decimal point. The highest numerical value to be displayed is 9999.
5.1.2
The polarity indication 4 works automatically. Only a polarity contrary to
the jack definition is indicated with „-". As of 12 V, polarity is indicated by
the
-LED or the
5.1.3
The range exceedance is indicated by „OL" or „-OL".
Attention, no other indication and warning in case of overload!
5.1.4
Ω/A key: Press the Ω/A key 6 to switch to the resistance measuring
range (Ω). Press the key again to switch to the current measuring range
(A). Press the key for 2 s to switch back to the voltage measuring range
(display - - - -).
5.1.5
The "HOLD" key 7 has three functions:
-
Storage of measured values „HOLD": The measuring result can be
stored by actuating the key 7 . The
pears on the display. By pressing the key 7 again, the device is
switched back to the measuring mode.
-
Measuring point illumination: Press and hold the "HOLD" key 7 for
2 s to switch on the LED of the measuring point illumination.
-
Acoustic signal for voltage measurement: Press and hold the
"HOLD" key 7 for 5 s to disable the acoustic signal for voltage
measurement, see section 8.3 "Acoustic signal for voltages >50 V
AC/ 120 V DC".
5.1.6
The nominal measuring rate of the BENNING CM 1-4 is 3 measure-
ments per second.
5.1.7
The BENNING CM 1-4 can be switched on by pressing the Ω/A key 6 or
the HOLD key 7 . The "- - - -" symbol on the digital display 4 indicates
readiness for voltage measurement, single-pole external conductor test
and continuity test. Under the following conditions, the device switches
on automatically:
Batteries with sufficient battery voltage being inserted:
-
Measuring voltage between +/L2 jack J and -/L1 jack 9 > 3 V or
< -8 V
-
Single-pole external conductor test detects the phase voltage
-
Continuity test detects a resistance < 1.8 kΩ to 2.7 kΩ
No batteries being inserted or battery voltage too low:
-
Measuring voltage between +/L2 jack J and -/L1 jack 9 >45 V AC
or > | ±35 V DC |
5.1.8
Automatic switch-off ("APO"):
The BENNING CM 1-4 switches off automatically after approx. 10 s if the
following conditions are met:
-
No key has been pressed.
-
The conditions for automatic switch-on are not met.
The BENNING CM 1-4 switches off automatically after approx. 30 s if the
following conditions are met:
-
"OL" is displayed in the resistance measuring range.
-
Display value <1 A in the current measuring range
5.1.9
Temperature coefficient of the measured value: 0.2 x (stated measuring
accuracy)/ °C < 18 °C or > 28 °C, related to the value for the reference
temperature of 23 °C.
5.1.10 The BENNING CM 1-4 is supplied by means of two 1.5 V micro batteries
(IEC LR 03).
5.1.11
The battery symbol on the digital display 4 continuously shows the re-
maining battery capacity via a maximum of three segments.
As soon as all segments of the battery symbol have disap-
peared and the battery symbol is flashing, the batteries must be
replaced by new ones immediately in order to prevent danger
for persons caused by incorrect measurements.
5.1.12 The battery life is sufficient for 1000 tests (alkaline battery, 30 s ON, 240
s OFF).
5.1.13 Dimensions of the BENNING CM 1-4: (L x W x H) = 220 x 57 x 35 mm
Weight: 200 g
5.1.14 The safety measuring leads with the contact tips correspond to the nomi-
nal voltage of the BENNING CM 1-4. The contact tips can be protected
by contact tips protectors and can be snapped onto the bottom of the
device for transport and measuring tasks.
5.1.15 Current clamp opening: 16 mm
07/ 2020