The pre-set logic functions and parameters are made taking account of a typical installation.
12.2.3) QUICK PROGRAMMING
-Enter the INST menu
-Verify that the parameter BOOM is correct: 3-5 for EVA.5, 7-8 for EVA.7
-Set the barrier position by means of the menu POS, by default the barrier is set as RIGHT BARRIER
-Enter the menu AUTO, confirm with <PG> and wait until the barrier has carried out the autoset of the parameters
-By means of the menus PAR and LOG, select the parameters and the logic functions wanted according to the type of installation in object
-IMPORTANT: After every change of the parameters FSTS. SLDO, SLDC, TSMO, TSMC, the barrier executes an opening maneuver
followed by a closing one in order to acquire the new values of current and torque, on the screen will appear the message <PRG>
12.3) PARAMETERS, LOGICS AND SPECIAL FUNCTIONS
The following tables describe the functions available on the control unit
MENU
Select the length of the boom installed on the barrier.
BOOM
Value expressed in meter from 3m to 5m (EVA5) or from 7m to 8m (EVA7)
According to the selected boom length, the optimal value of speed will be set.
Set the closing direction of the barrier (see fig. 2)
The symbol 0--- indicates right barrier (R/RIGHT) DEFAULT
The symbol ---0 indicates left barrier (L/LEFT)
Pos
Verify the opening direction of the boom and in case reverse it. Every change
of this function automatically implies the starting of a new AUTOSET proce-
dure.
MENU
Automatic closing time. Enabled only with logic "TCA"=ON.
TCA
At the end of the set time, the control unit commands a closing maneuver .
Adjusts the opening and closing speed of the barrier (standard speed, before the
FSTS
slowdown phase).
Adjusts the slowdown speed of the barrier during the opening phase* (Fig.11 -slow
sldo
Open).
Adjusts the slowdown speed of the barrier during the closing phase * (Fig.12 -slow
sldc
Close).
Sets the starting point of the slowdown during the opening phase (Fig.11- beginning
tsmo
of the slow Open). The value is expressed in percentage on the entire stroke.
Sets the starting point of the slowdown during the closing phase (Fig.12- beginning of
tsmc
the slow Close). The value is expressed in percentage on the entire stroke.
PMO
Adjusts the motor torque applied to the barrier during the opening phase.*
PMC
Adjusts the motor torque applied to the barrier during the closing phase.*
Adjusts the motor torque applied to the barrier during the slowdown in opening phase
PSO
* (Fig.10 - Slow Open).
Adjusts the motor torque applied to the barrier during the slowdown in closing phase
PSC
* (Fig.11 - Slow Close).
Adjusts the intervention threshold of the anti crushing device (Encoder) during the
SeaU
normal speed*.
0:Off -1: minimum sensitivity - 99: maximum sensitivity
Adjusts the intervention threshold of the anti crushing device (Encoder) during the
SEAR
slowdown speed*.
0:Off -1: minimum sensitivity - 99: maximum sensitivity
Activation time of the courtesy light contact. Value expressed in seconds. At the begin-
tls
ning of each maneuver the contact latches for the set time.
See the description of AUX1 parameter.
Sets a short reversion after reaching the limit switch in open position. Can be useful
saso
for facilitating the manual release.
Sets a short reversion after reaching the limit switch in close position. Can be useful
sasc
for facilitating the manual release.
INSTALLATION (inst)
FUNCTION
PARAMETERS (PAR)
FUNCTION
MEMO
MIN-MAX-(Default)
3/5 -7/8 (3-5)
= RIGHT
--- 0
= LEFT
0---
( RIGHT )
MIN-MAX-(Default)
MEMO
1-240-(20s)
50-99-(99)
20-70-(50)
20-70-(50)
1-99-(20)
1-99-(20)
1-99-(20)
1-99-(20)
1-99-(20)
1-99-(20)
0-99-(0%)
0-99-(0%)
1-240 (60)
0-5 (0)
0-5 (0)
27