12) CP.EVA2 CONTROL UNIT
12.1) WIRE DIAGRAM
Wire connections shown in Fig. 15 are described hereunder:
TERMINALS
Function
ANT-SHIELD
Antenna
BAR
Not used
AUX
Auxiliary output AUX 1 Output with N.O. contact configurable by means of the logic AUX 1
24V
24 Vdc
MOT
Motor
N/A
P.P.
Step by step
CLOSE
Close
OPEN
Open
PHOT
Photocell
STOP
STOP
SWC
Closing limit switch
SWO
Opening limit switch
COM
Common
24Vdc output for bar
AUX2
light
BLINK
Blinker
ABS ENC
Encoder input
M1
24Vdc INPUT
12.2) PROGRAMMING
The programming of the various functions of the control unit is carried out using the LCD display on the control unit and setting the
desired values in the programming menus described below.
The parameters menu allows you to assign a numerical value to a function, in the same way as a regulating trimmer.
The logic menu allows you to activate or deactivate a function, in the same way as setting a dip-switch.
12.2.1) TO ACCESS PROGRAMMING
1-Press the <PG> button to enter the first Installation menu "INST".
2-Choose with <+> or <-> button the menu you want to select (see menu at page 10-11)
3- Press the button <PG>, the display shows the first function available on the menu.
4 - With the <+> or <-> button, select the function you want.
5 - Press the button <PG>, the display shows the value currently set for the function selected.
6 - With the <+> or <-> button, select the value you intend to assign to the function.
7 - Press the button <PG>, the display shows the signal "PRG" which indicates that programming has been completed.
12.2.2) PROGRAMMING NOTES
Simultaneously pressing <+> and <-> from inside a function menu allows you to return to the previous menu without making any chan-
ges. Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
After waiting 120s the control unit quits programming mode and switches off the display.
When the board is switched on, the software version is displayed for around 5 sec
26
TERMINAL BLOCK 1
Description
Connection for the antenna of the built in receiver (ANT-signal/SHIELD-shield).
In case of use of an external antenna it is necessary to remove the pre-cabled cable from
the terminal ANT
Accessory power supply 24Vdc 500 mA maximum
Motor connection: 24Vdc.
Not used
TERMINAL BLOCK 2
Input for step by step command (N.O. contact) .
Input for close command (N.O. contact) .
Input for open command (N.O. contact), It is possible to connect a timer for programmed
openings.
Input for photocells enabled during opening and closing phase (N.C. contact).
Input for STOP command (N.C. contact).
Input for closing limit switch (N.C. contact).
To be used ONLY FOR BARRIER WITH ELECTROMECHANICAL LIMIT SWITCHES. If not
used it is NOT NECESSARY TO BRIDGE the input to the common COM.
Input for opening limit switch (N.C. contact).
To be used ONLY FOR BARRIER WITH ELECTROMECHANICAL LIMIT SWITCHES. If not
used it is NOT NECESSARY TO BRIDGE the input to the common COM.
Common for all the input commands and the limit switches .
24Vdc output for the bar flashing light (EVA.L) the flashing mode can be set by means of the
logic LBAR.
Output 24Vdc 15W max. for flashing light connection (EVA.LAMP) to be installed on the top
cover of the barrier.
TERMINAL BLOCK 3
Absolute encoder input, pre-cabled by factory.
TERMINAL BLOCK M1
24Vdc input for powering the CP.EVA2.In case of use of the SUN SYSTEM it is necessary to
connect the 24Vdc output of the SUN.SY to M1 (see the KSUN instructions)