• Option: put a lid
on the dustbin.
9
• Empty the dustbin.
• Dispose of the contents of the dustbin in accordance with
state or local regulations.
• Install the empty dustbin in reverse order.
6.3
Emptying the sparkTrap
Personal protective equipment (PPE)
>2 mm
Wear respiratory protection and protective
gloves when you empty the SparkTrap.
To empty the SparkTrap, proceed as follows.
• Loosen the draw latches and remove the lid.
• Use an industrial vacuum cleaner
• Close the SparkTrap.
6.4
Filter replacement
Replacement of the filter cartridges is necessary when the
pressure is more than preset value. Default setting: 2000 Pa.
Replace the two filter cartridges at the same time.
Personal protective equipment (PPE)
Wear respiratory protection and protective
gloves when you replace the filter
cartridges.
WaRNiNg
Do not replace the filter cartridges while the fan is
running.
To replace the filter cartridges, proceed as follows.
• De-energize the filter unit.
• Disconnect the compressed air.
• Fully disconnect the unit from the mains.
• Loosen the star knob (F) and disassemble the lid (E), the
nut (D) and the metal washer (C).
• Remove the filter cartridges (B) and put them in the plastic
bag in which the replacement filter cartridge is supplied.
• Seal the bags securely.
• Put new filter cartridges on the cartridge holders (A) and
attach them with the disassembled parts.
• Clean the environment of the unit.
• Push the
rEsEt AlArM
seconds to reset the filter hour counter
A
B
Fig. 6.2
Filter replacement
9. Optionally available; article no. 0000111622
10. The industrial vacuum cleaner must meet dust class H according to
EN 60335-2-69.
11. PLC display shows: "Filter hours = 0" (scroll menu)
0000112315/011017/0 MDB-2/HV
max. 2 mm
to empty the SparkTrap.
10
>2 mm
button (ref. Fig. 5.1E) during 10
.
11
C
D
E
F
aTTENTiON
Make sure that the front of the filter cartridge
aligns
with the filter housing, so that the lid closes
*)
well. If this is not the case, the filter cartridge is not
positioned correctly. This can cause leakage and less
efficient operation of the filter cartridge.
tolerance: max. 2 mm (0.1 in.)
*)
>2 mm
7
TROUblEsHOOTiNg
symptom
Problem
The system
No filter
stops
cleaning
unexpectedly
takes place
Control light
The system
FAIlurE (ref.
does not
Fig. 5.1A) is
function
on; message
on PLC:
- "clogged
filters"
- "no air
pressure"
The fan
Extraction
makes a
capacity
humming
insufficient or
sound, but
no extraction
does not run
at all
Poor
The unit does
extraction
not function
capacity
properly
Pollution of
the facility
No filter
cleaning
Hissing
No filter
sound.
cleaning
max. 2 mm
>2 mm
Possible cause
solution
No compressed
Repair the
air available or
compressed air
air pressure too
supply
low
Clogged filter
Replace the filter
cartridges
cartridges; refer to
section 6.4
No compressed
Repair the
air available or
compressed air
air pressure too
supply
low
Motor uses 2
Repair the phase
phases instead
connection
of 3
Inverted
Change the
direction of
direction of rotation
rotation of the
motor
Clogged filter
Replace the filter
cartridges
cartridges
Filter
Replace the filter
cartridge(s)
cartridges(s) or
ripped or placed
place them
incorrectly
correctly
Loose
Repair the
compressed air
compressed air
connection
connection
No compressed
Repair the
air available or
compressed air
air pressure too
supply
low
Membrane
Replace the
valve(s)
membrane valve(s)
defective
Membrane
Replace the
valve(s)
membrane valve(s)
defective
EN - 9