Technical data
Technical data GM-TA (PCN 1244-017783)
Supply voltage
Relay control
heating cable
Relay alarm
Power consumption
Terminal size
Storage temperature
Operation ambient
temperature range
Switching hysteresis
Accuracy
Programmable parameters
Temperature setting range
Lower temperature range
Post heating time
Operating modus
Enclosure thermostat
Installation
IP rating
Ambient sensor GM-TA-AS (PCN 1244-017965) included
IP rating
Installation
Ambient sensor type
Approvals
CE, UKCA, RoHS, REACH
Error codes
E1
E2
230 Vac, +10%/–10%, 50 Hz
Potential-free (max 230 Vac +10%),
max 16 A (resistive load)
Potential-free (max 230 Vac +10%),
switch-over contact, max 8 A
Max 5 VA
Max. 2,5 mm
, screwed
2
–20°C to +50°C
–25°C to +40°C
+/– 1 K
+/– 1,5 K incl. sensor accuracy
Set point: 0°C to 6°C
–5°C to –25°C
0 to 3 hours
On: normal operation
Off: relay off (open)
Test: relay On (30 minutes)
DIN-rail-mounted
IP 20
IP 65
Wall mounted / outdoors
202AT +/–1% NTC 2.0 K @ 25°C
Ambient sensor open circuit or
short circuit / Check connections
and resistance
Internal error / Replace GM-TA