Mini Anemometer / English
HOLD/
button: Short press to hold the current data; Long press to activate or
deactivate backlight.
MAX/ MIN button: Short press to record Maximum, Minimum and Average readings of
temperature and Air velocity.
Note: MAX/ MIN button is deactivated when hold the current readings.
4.Display Layout
: Bluetooth symbol
: Low battery indicator
: Timing power off symbol
MAX: Maximum reading of temperature air velocity
MIN: Minimum reading of temperature air velocity
AVG: Average reading of temperature air velocity
HOLD: Hold the displayed temperature/ air velocity readings.
o
o
C/
F: Temperature measurement unit
m/s, ft/min, km/h, MPH, knots: Air velocity measurement unit.
Larger LCD digits at botton of display is Air Velocity readings
Smaller LCD digits at top, right of display is Temperature readings
Data Hold
Short press hold button to freeze the temperature and velocity readings, meanwhile,
hold symbol displayed on LCD when measures. Press hold button again to return normal
measurement.
Temperature and Air velocity measurement
1. Turn on the instrument by pressing power on/off button.
2. Press UNITS button to select unit of measurement. Note: After power on, the meter
wilI display the presetb unit before last power off.
3. Put the instrument in environment that is to be measured.
4. Observe readings on the LCD display, The Iarger digits displayed on main LCD is Air
VeIocity reading.
The smaller digits displayed on upper right LCD is temperature reading.
MAX/MlN/AVG reading
1. Press MAX/MIN button for the first time, the instrument will enter Max tracking mode.
The tracked max reading will display on the LCD.
2
All manuals and user guides at all-guides.com
2. Press MAX/MIN button for the second time, the instrument will enter Min tracking
3. Press MAX/MIN button for the third time, the instrument will enter Avg tracking mode.
4. Press MAX/MIN button for the fourth time, the current reading will display on the LCD.
Note: Avg mode will automatically stop in 2 hours and the instrument will auto power off
Long press Bluetooth button to activate bluetooth function. The instrument can transmit
measured datas and instrument status to software and the software can controI the
instrument.
The instrument will automatically turn off in order to lengthen the battery working Iife.
When symboI
1. Open the battery compartment with a suitable screwdriver.
2. Replace 9 V battery.
3. Mount the battery compartment again.
4. Specifications
31/01/2018 Version No. 001
31/01/2018 Version No. 001
mode. The tracked min reading will display on the LCD.
The tracked average reading will display on the LCD.
Bluetooth communication
appears on the LCD, please replace the old battery with new ones.
Air velocity
Range
m/s
1.10 – 25.00 m/s
km/h
4.0 – 90.0 km/h
ft./min
220 – 4920 ft./min
MPH
2.5 – 56.0 MPH
knots
2.2 – 48.0 knots
o
o
Air temperature
-10 – 60
C (14~140
F)
Mini Anemometer / English
Resolution
Accuracy
0.01 m/s
±(3%+0.30 m/s)
0.1 km/h
±(3%+1.0 km/h)
±(3%+40 ft./min)
1 ft./min
0.1 MPH
±(3%+0.4 MPH)
0.1 knots
±(3%+0.4 knots)
o
o
o
o
0.1
C/
F
2.0
C (4.0
F)
3