Alpine S-A60M Mode D'emploi page 21

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Cautions on Power Supply Wires
aker
Use the specified wire size according to the total fuse capacity of the amplifier to be installed and the wire
length.
For details on the wire size to be used, refer to the supplied "Cautions on Power Supply Wires Connection"
and the following connection example.
Connection example when installing an amplifier alone
• When the wire length from the amplifier to the vehicle's battery is 5 m
Wire size used for (A):
S-A60M/S-A55V: 4 AWG/21 mm
S-A32F: 8 AWG/8 mm
• External Fuse capacity: Make it equal to or larger than the fuse capacity of the amplifier
S-A60M/S-A55V: equal to or larger than 60 A
S-A32F: equal to or larger than 40 A
Connection example when installing two amplifiers with a fuse capacity of 60 A
and one amplifier with 40 A
• When the wire length from each amplifier to the distribution block is 1 m
Wire size used for (B): 8 AWG/8 mm
• When the wire length from the distribution block to the vehicle's battery is 4 m
Wire size used for (C): 1/0 AWG/53 mm
• External Fuse capacity: Make it equal to or larger than total fuse capacity of the number of amplifiers
d due to
installed
ot work
60 A + 60 A + 40 A = equal to or larger than 160 A
n
no pair
NOTE:
• If the length of the power and ground cables exceed 1 m, or if you connect more than one amplifier, a
distribution block should be used.
2
Amplifier
Amplifier
(e.g. 60 A)
Amplifier
(e.g. 60 A)
Amplifier
(e.g. 40 A)
2
(A)
Vehicle's chassis
2
2
(or 4 AWG × 2/21 mm
(B)
Distribution block
Vehicle's chassis
ALPINE S-A60M/S-A32F/S-A55V 68-35792Z59-A (EN/FR/ES)
External Fuse
Vehicle's battery
2
× 2)
(C)
External Fuse
Vehicle's battery
EN
FR
ES
19
-EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

S-a32fS-a55v

Table des Matières