Rat ed out put power(W)
Volt age(V)/ f requency(Hz) range
Maximum out put current (A)
Maximum out put f ault current
Output
(AC )
AC inrush current
Maximum out put overcurrent
prot ect ion(A)
Power f act or
Harmonic dist ort ion
Cooling met hod
Maximum ef f iciency
European ef f iciency
MPPT ef f iciency
Prot ect ion degree
Power consumpt ion at night
Isolat ion mode
Saf et y class
Overvolt age prot ect ion class
Invert er t opology
System
Pollut ion degree
Operat ion t emperat ure
Relat ive humidit y
Max. alt it ude(m)
Display
Syst em language
Communicat ion
DC t erminal
Noise dB(A)
Inst allat ion mode
Grid st andard
Others
Saf e cert if icat e / EMC cat egory
Input overvolt age prot ect ion, input overcurrent prot ect ion, DC isolat ion monit oring, DC monit oring, grounding f ault current monit oring,
Protection
4000
4000
6.4
12.7
97.20%
97.30%
97.00%
97.00%
DIN VDE 0126-1-1 : 2013 , VDE-AR-N 4105 : 2011 , DIN VDE V 0124-100 : 2012 , IEC
61727 ( IEC62116 ) , AS/ NZS 4777.2 : 2015 , NB/ T32004-2013 , IEC 60068-2-1 : 2007 , IEC 60068-
2-2 : 2007 , IEC 60068-2-14 : 2009 , IEC 60068-2-30 : 2005 , IEC 61683 : 1999 , C10/ 11 : 2012
IEC 62109-1 : 2010 , IEC 62109-2 : 2011 , EN 61000-6-2: 2005 / EN 61000-6-3:2007/ A1:2011
grid monit oring, island prot ect ion, short circuit prot ect ion, overheat ing prot ect ion et c.
5000
5000
320~460Vac, 50Hz(47~51.5Hz) / 60Hz(57~61.5Hz)
8
265A @ 34ms
Less t han 10 A
15.8
-0.80~+0.80(Adjust able)
< 3% (rat ed power )
Nat ural cooling
97.30%
97.40%
97.00%
97.00%
99.90%
IP65
< 1W
Transf ormerless
I
AC:III,PV:II
Non-isolat ed
℃
℃
300.00%
(-25
~+60
), (Derat e af t er 45
4~100%, Condensat ion
≤ 2000 , (Derat e if t he alt it ude > 2000)
LED/ LCD, backlit display
English, Chinese, German, Dut ch
RS485 (st andard),Et hernet , WiFi (opt ional)
BC03A / BC03B
≤ 30
Wall inst allat ion
6000
8000
10000
9.6
12.8
16.1
19
25.3
31.8
Air cooling
97.50%
97.60%
98.20%
97.00%
97.00%
97.60%
℃
)
<50