S ta rt : 2 01 2 - 0 1 - 0 1
User period
E nd : 2 01 2 - 0 2 - 0 1
P-Lmt
Mode
LmtPower
P.Factor
Set power
U se r Pe ri od
1
Input password
0000
set power
Limit Mode: Invalid
Invalid
Auto
Manual
Limit Power
100%
Power Factor
Grid Tied Mode
Normal Mode
Power Factor:1.00
Enter into the interface and edit the
user period through "
And then press "ENT" again to the
next bit. After editing, press "ENT" to
save the edition and press "ESC" to
exit.
Of which, the setting time and date
needs to be later than the system
setting, and the start time needs to
be earlier than the end time.
The setting date and time is used for
the statistical information.
The password is needed when enter
into the interface of "Set power". Get
the password from the supplier if
①P-Lmt Mode: invalid (limited power
necessary. There are 3 submenus:
function is invalid),auto (special for
of output value manually); ②
single phase) ,manual (set the limit
LmtPower: this function is only valid
when the P-Lmt Mode is manual, the
percentage is that of the rated power
100%; ③Power factor: includes
and the setting range is from 10% to
normal model (default value "1"),
current advanced mode and current
hysteresis mode and the setting rage
is -0.9-0.99.
" or "
".