All information is displayed on the LCD screen. The background illumination of LCD
screen will go out to save power if there is not button operation in 15 seconds. But it
can be activated by pressing any button. Press "ENT" to enter into the main interface if
the background illumination is on. All parameters can be viewed and set on the
interface.
There are main interface and menu interfaces on the LCD screen, of which the main
interface is the default one after power on, while the menu interfaces are used to
watch and set parameters or other manual operation, such as viewing the monitoring
parameters, history record, system information, statistics and fault information and
setting the displayed language, time, communication address, password and factory
defaults.
The main interface of the LCD screen is shown as the Figure 24:
(1) The curve displays the power changing at the current day;
(2) The words on the screen display the current key parameters of the inverter. Three
lines of words are displayed at a time, but if the inverter is in operation or stand-by
state, the words are rolling forward at every 3s. And the user can press " " or "
look up the information freely;
(3) State display area displays current running state of the inverter, which can display
"self-inspection", "grid-connected power generation", "alarm", "fault" and "OFF" state;
(4) Dynamic fault code and menu entrance. When the state display area displays
"alarm" or "fault", the dynamic fault code area will display corresponding fault code
(display up to 8 fault codes).
FUNCTIONS OPERATION
Most of the parameters can be viewed and set through the LCD screen and operation
panel.
MONITORING PARAMETERS
Press "
" and "
" in the main interface to select "Monit Param", and then press "ENT"
to view the parameters which is shown in Figure 26. Go the front or next page through
"
" and "
" and return through "ESC".
Text Parameter
Display Area
Status Area
Figure 24 Main interface
M ai n Me nu
M on it P ar am
S ta ti st ic s
S et up
S ys te m In fo
F au lt I nf o
Figure 25 Main interface
C ur re nt S ta te
E - t od : 0 W h
$ - t od : € 0 . 0 0
P - i n : 0 . 0 0 k W
Figure 26 Monitoring parameters
Fault Code
" to