fault
Unrecoverable
fault
Artificial turned
off
Note
Please refer to detailed fault information and troubleshooting for more info.
OPERATION PANEL
There are 4 buttons on the panel:
(1) "ESC", exit and return ;
(2) "
", back to the front page and data increasing;
(3) "
", to the next page and data decreasing;
(4) "ENT", enter.
LCD SCREEN
Inverter stand-by. The public grid fault(A001, A003,
Run
Warn
A004, A005or A006);
Fault
Yellow indicator blinks in every 0.5s, others off
(1) Inverter stand-by. Temperature abnormal(E006);
Run
(2) Recoverable Inverter stand-by. DC input fault
Warn
(E001);
Fault
Yellow indicator keeps on, others off
Hardware or software fault (E003, E004, E005, E008,
Run
E009, E011, E013 or E015). De-couple the inverter from
Warn
the system before maintenance.
Fault
Red indicator blinks in every 0.5s, others off
Current-leakage or unqualified output power energy of
the inverter (E007, E010, E014, E017, E018 or E020).
Run
Warn
De-couple the inverter from the system before
Fault
maintenance.
Red indicator keeps on, others off
Run
Stop after the communication or panel command. All
Warn
indicators are on.
Fault
Figure 23 Operation panel