6. REMOVAL
- The motor unit can be removed from the pump body without having to disconnect the pump's suction and return
pipes.
- To remove the Motor unit from the pump body, remove the screws joining them together.
7. TROUBLESHOOTING
1. The pump is not primed
2. The pump releases only a small flow of water
3. The pump makes a noise
1 2 3 4 5 6
Victoria Dual Speed
- ASTRALPOOL
All manuals and user guides at all-guides.com
CAUSES
Air entering the suction pipe
Filter cap badly sealed
Inverted motor turning
Wrong voltage
Pre-filter blocked
Load loss in the installation
Pump incorrectly secured
Motor blocked
Increased temperature in the
terminal box due to electric
arc
The thermal protection trips
Incorrect terminal box
connections
4. The pump will not start
5. The motor is making a noise but will not start
6. The motor is stopped
SOLUTIONS
Check the condition of connections and seals
on the suction pipe
Clean the filter cap and check the condition of the
Invert 2 power phases
Check the voltage on the characteristics plate and
that of the mains
Clean the filter
Prevent parts from causing load loss wherever
Secure the pump correctly
Remove the motor and contact the technical service
Check the terminal box connections
Connect the cables correctly to the terminal boxes
Tighten the cable correctly to the terminal / Adapt
the size of the cable connection to the terminal box
rubber seal