4. Maintenance
Foam cup: Depending on the organic load, the cup should be cleaned daily to weekly.
•
Reaction pipe: This only needs occasional cleaning. We recommend intervals of 6 to 12
months.
Venturi pump: The maintenance of the pump should be done at the same time as the reaction
•
pipe:
Drain the water out and dismantle the pump. Flush the pump housing and the needle wheel
with clean water.
The same should be done with the air injection nozzle.
5 Failures
Failures may arise if:
- the ratio between supplied air and the water volume is not correct.
Cause:
The air injection nozzle is clogged or the pump chamber containing the needle wheel is dirty.
Action:
Dismantle the venturi pump, clean it thoroughly, carefully clean the air injection nozzle with a
thin brush or blunt instrument and re-assemble the pump again.
- the venturi pump does not re-start after an interruption of the power supply.
Cause:
The water pressure is too high.
Action:
Let the water out up to the height of the pump to lower the water pressure.
Re-start the pump.
7. Warranty
Should any defect in material or workmanship be found within twelve months of the date of
purchase AB Aqua Medic GmbH undertakes to repair or, at our option, replace the defective part
free of charge – always provided the product has been installed correctly, is used for the purpose
that was intended by us, is used in accordance with the operating instructions and is returned to us
carriage paid. The warranty term is not applicable on the all consumable products.
Proof of Purchase is required by presentation of an original invoice or receipt indicating the dealer's
name, the model number and date of purchase, or a Guarantee Card if appropriate. This warranty
may not apply if any model or production number has been altered, deleted or removed,
unauthorised persons or organisations have executed repairs, modifications or alterations, or
damage is caused by accident, misuse or neglect.
We regret we are unable to accept any liability for any consequential loss.
Please note that the product is not defective under the terms of this warranty where the product,
or any of its component parts, was not originally designed and / or manufactured for the market in
which it is used.
These statements do not affect your statutory rights as a customer.
If your AB Aqua Medic GmbH product does not appear to be working correctly or appears to be
defective please contact your dealer in the first instance.
Before calling your dealer please ensure you have read and understood the operating instructions.
If you have any questions your dealer cannot answer please contact us.
Our policy is one of continual technical improvement and we reserve the right to modify and adjust
the specification of our products without prior notification.
AB AQUA MEDIC GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany
12
All manuals and user guides at all-guides.com
- Technical changes reserved – 04/2010