Settings
2. Activating/deactivating Eco mode:
■
Activate
Activate Eco mode.
■
Deactivate
Deactivate Eco mode.
7.4
Setting the rain sensor (Robolinho 450
W/700/1200/2000)
NOTE Mowing when the grass is dry re-
duces soiling. By activating the rain sensor and
setting a delay time, it is possible to prevent the
appliance mowing when the grass is wet.
If the rain sensor is activated, the appliance
moves back into the base station when the rain
begins. It remains there until the rain sensor has
dried. Then it waits for the time period that is set
as the delay before it continues mowing. The
sensitivity of the rain sensor is adjustable.
* Rain sensor
1.
or
2. Activating/deactivating the rain sensor:
■
Activate
or
Activate the rain sensor.
■
Deactivate
or
Deactivate the rain sensor.
3. Setting the delay of the rain sensor:
■
* After rain delay
or
■
xx hours xx minutes
Select the required value for the delay
with
or
4. Setting the sensitivity of the rain sensor:
■
* Rain sensitive
or
■
Select the required value for the sensitivi-
ty with
or
7.5
Setting the mowing program
7.5.1
Setting the mowing program – General
1. Call up the main menu with
* Programs
2.
or
3. Select the menu item with
cept with
.
4. Carry out the settings.
Note: The menu items are described in the
following sections.
495439_a
:
:
:
:
and accept with
and accept with
.
or
and ac-
7.5.2
Setting the start points
Teaching-in start points
1. Place the appliance in the base station.
2. Switch on the appliance with
3. Call up the main menu with
4.
or
5.
or
6.
or
7.
or
point teaching
■
moves along the boundary cable.
■
has reached the required start point. The
start point is stored.
8.
or
start point has been specified during the
teaching-in movement. If no start point has
been specified here, the start points are auto-
matically specified.
9.
or
the last start point has been reached.
Manually specifying start points (05)
The first start point (05/X0) is pre-set and is 1 m
to right of the base station. Other start points can
be defined after this point (see technical data).
.
When specifying the start points, heed the follow-
ing:
■
Do not set start points too far from the base
station or too close to one another (06/f).
■
Only use as many start points as necessary.
.
1.
or
2.
or
Select one digit in sequence with
and always accept with
3.
or
Select one digit in sequence with
and always accept with
4. If necessary, specify further start points.
5. Return to the main menu with
* Programs
* Entry Point
* Interactive teach
* Start interactive entry
:
Start
or
. The appliance
Set
or
when the appliance
Set entry point 1
Entry point x: XXm
* Entry Point
* Point X1 at [020m]
* Point X2 at [075m]
.
.
if no
if
or
.
or
.
.
51