Water outlet
Water outlet AV is DN 70 on the machine, the fitting to
the machine is DN 70. Short-term thoughput 200
l/min.
Foam compensator SK
In the event of over sudsing, foam may escape
through the vapor vent. To drain the foam, a drain
with siphon can be fitted using off-the-shelf piping
materials.
Installation examples
All manuals and user guides at all-guides.com
Installation Instructions
Electrical connection
All electrical work must be performed by a
qualified service technician in accordance with
applicable codes and standards.
The connecting terminal is located behind the cover.
The machine must only be connected to the voltage
and frequency shown on the data plate.
The machine is equipped with a multi-tap
transformer.
Steam heated washers are factory set to 3 phase,
208 V, 60 Hz
They can be converted to 3 phase, 240 V, 60 Hz by a
Miele Service Technician.
Electrically heated washers are factory set to 3
phase, 230 V, 50/60 Hz
They can be converted to 3 phase, 208 V, 60 Hz by a
Miele Service Technician.
If the appliance is hard wired, a multiple-pole
separator must be installed. An appropriate separator
is a switch with a contact opening of at least 3 mm.
This includes circuit breakers, fuses and switches.
The plug connection or the separator must be always
be accessible.
Connection should be made in accordance with the
wiring diagram and the installation diagram to a
suitable isolator, with an on-off switch which is easily
accessible for servicing. These diagrams are
important for the correct electrical functioning of the
machine.
Potential equalization
A potential equalization must be provided if the leak
current is >10 mA.
The electric heating is factory-set to
9 kW
PW 6107
15 kW
PW 6137, PW 6167
18 kW
PW 6207.
To activate the heating the water level in the drum
must be 2" (50 mm) high.
A motor overload protection is located in the motor
winding.
See the enclosed wiring and installation diagrams.