5. Assembling the interior control cabinet
5.1
Selecting the location
When selecting the location for the control cabinet, the following must be considered:
The control cabinet must be mounted above the highest water level in the tank to avoid over-
flowing and water intake by gravity in case of an accident
The system generates noise! When operating, the air compressor generates continuous
noise.
The machine cabinet requires a separately protected electrical connection (16 amp, slow
blow) The electrical connection serves as a mains disconnecting device and must be easily
accessible at all times. Additional electrical fixtures on the same fuse may disrupt operation.
The location of the machine cabinet must be a dry, cool and well-ventilated room. The cabi-
net, in particular the ventilation vents and the circuit breaker, must not be covered and must
be freely accessible for maintenance work.
The air hoses should not be longer than 20 metres.
5.2
Assembling the steel cabinet
Technical data
Protection class: IP44
Material:
Sheet steel 1.5 mm,
powder coated
Colour:
RAL 7032
Dimensions W x H x D [in mm]:
500 x 500 x 300 (interior cabinet 1)
600 x 600 x 330 (interior cabinet 2)
800 x 675 x 500 (interior cabinet 3)
5. Assembling the interior control cabinet
H
B
/
T