5.4
Troubleshooting
Error
No mains voltage available
Mains power fuse has tripped
Connection cable is damaged
Pump is not running
Float switch is defective
Overheating
Multi-vane
Dirt, solids have become lodged between the
impeller is blocked
multi-vane impeller and the spiral housing.
Intake cage is blocked
Reduced pump-
Multi-vane impeller is worn
ing capacity
Vent is blocked
016-211_01
Cause
Remedial measures
Check the mains voltage
Switch fuse on again
Repair only by qualified electricians/service
partners
Contact customer service
Submersible pump switches back on again
automatically after the temperature has
dropped
Clean the pump
Clean the pump
Replace the multi-vane impeller
Clean the vent
25 / 52