ATTENTION
Always unplug pump before any work is un-
dertaken on the pump.
Regular cleaning of the exterior of the
pump assures proper operation as well as
the maximum possible pump performance.
The float switch should also be kept clean
and free of debris in order to assure proper
operation.
The suction basket (base of pump) assures
that no solids or unwanted matter enters
the pump's rotating impeller.
ATTENTION
Never disassemble the pump (this work
should only be handled by the manufacturer
or a service company). Improper work on
the pump could damage the sealing gasket
which may cause oil to leak out of the pump
(valid only for KTP 500).
In order to clean the impeller first unscrew
the suction basket and remove. The impeller
3. Cleaning / Maintenance
can now be cleaned and freed from any de-
bris. Clean the intake area of the pump and
rinse with clean water.
In accordance with regulations concerning
wastewater systems, the KESSEL KTP 300,
500 and GTF 1000 may not be used to pump
wastewater containing raw sewage or flam-
mable or explosive fluids.
KESSEL – KTP 500 Titanium submersible
pump:
This pump model is designed to pump ag-
gressive fluids / mediums
ATTENTION
DO NOT USE with Nitroethylene or Trichlor-
ethylene!
ATTENTION
Buse in swimming pools or ornamental
ponds is only allowed if VDE 0100 49d re-
gulations are followed – please contact your
local electrician!
17
Only the KTP 500 is filled with oil for lubrica-
tion and cooling of the pump – in the case of
damage to the pump or the pump body, this
oil can leak from the pump and contaminate
the pumping medium!
Before placing the KESSEL Submersible
pump KTP 300, 500 or GTF 1000 in opera-
tion please technically check if the following
electrical protection measures are in place:
Grounding, insulating transformer, fault
current protection switch (these must com-
ply with EVU regulations and be in perfect
working order. (EVU – local electrical power
supplier)
Keep the pump's power plug away
from water or moisture!
For use in a collection tank / chamber:
In the case that the plug is in danger of
being submerged or getting wet, re-con-
nect the power supply in a dry, protected
location.