Error indicator

Under normal operating conditions, the error indicator lights up continuously in green (Figure 2/3 - 3). In the case of an
error, the indicator flashes orange.
If E0 is indicated on the display, this means that the temperature sensor (NTC) is defective. Please contact Truma Service.
Flash code
Error
(every four seconds)
1 x flash
Low voltage
2 x flash
Fan problem
3 x flash
Compressor starting problem
4 x flash
Low fan speed
5 x flash
Appliance is overheating
If these measures do not rectify the problem, please contact Truma Service.
EN
18
Description / solution
– Check the power supply (test another power source / socket).
If this eliminates the problem, the original power source may
be defective.
– Ensure that the cable between the battery and appliance has
a minimum diameter of 1.5 mm². If the distance is greater
than 2 m, the cable diameter must be at least 2.5 mm2.
– The fan is defective and needs to be replaced by a specialist.
– Unplug the appliance and leave unplugged for ten minutes.
– Check the power supply (test another power source / socket).
– The compressor is defective and needs to be replaced by a
specialist.
– Reduce the number of products in the appliance.
– Store the appliance in a cooler location.
– Clean air vents / ensure that the compressor is sufficiently
ventilated.
– The fan is defective and needs to be replaced by a specialist.
– Store the appliance in a cooler location.
– Clean air vents / ensure that the compressor is sufficiently
ventilated.
– The fan is defective and needs to be replaced by a specialist.