Temperature setting

Temperature range: –22ºC to +10ºC
– Press the "Change fridge compartment / mode"
button once and set the desired temperature with the
"Temperature setting" buttons.
– In Dual Zone models, press the "Change fridge
compartment / mode" button again and set the desired
temperature in the second fridge compartment with the
"Temperature setting" buttons.
– Press the "Turbo button" to increase the cooling power of
the compressor. The fridge compartment is therefore cooled
down faster.

Changing the temperature unit

– Press the "Change fridge compartment / mode" button
twice (three times for Dual Zone models) and set the
desired temperature unit °F or °C with the "Temperature
setting" buttons.

Setting the battery discharge prevention

– Press the "Change fridge compartment / mode" button
three times (four times for Dual Zone models) and select the
desired battery voltage protection with the "Temperature
setting" buttons.
Battery
discharge
On
preven-
(12 V)
tion:
LO
11.1 ±
10.1 ±
0.3 V
0.3 V
MED
12.2 ±
11.4 ±
0.3 V
0.3 V
HI
12.6 ±
11.8 ±
0.3 V
0.3 V

Bluetooth setting

– Press the "Change fridge compartment / mode" button
four times (five times for Dual Zone models) and switch
the Bluetooth on and off with the "Temperature setting"
buttons.
– Press "Change fridge compartment / mode" button and
"+" button simultaneously for three seconds to change
Bluetooth mode with the "Temperature setting" buttons.
CLO
Connection only possible via Bluetooth if the QR
code provided is scanned.
OPE
The appliance can be found via the Bluetooth
function on mobile devices
Off
On
Off
(12 V)
(24 V)
(24 V)
23.3 ±
21.5 ±
0.3 V
0.3 V
25.3 ±
24.1 ±
0.3 V
0.3 V
26.2 ±
24.6 ±
0.3 V
0.3 V
Power supplies and emergency override
switch
Power supplies, 230 V fuse, USB connection
and emergency override switch
AC 100-240V
DC 12V/24V
Figure 4
230 V fuse
The 6.3 A fuse must only be replaced by a
specialist.
Emergency override switch
During normal operation, the switch is set to "NORMAL
USE". If there are problems with the display or electronic
control unit, move the switch to "EMERGENCY OVERRIDE".
In this way, the appliance continues to work with full cooling
power (risk of frost!).

DC connection on the rear

DC 12V/24V
Figure 5
The second DC connection enables optimum positioning of
the appliance.

Two-way opening and removable lid

Removing the lid

– Open the lid and push against the stop until the lid can be
removed.
Figure 6
emergency
normal
override
use