5.1
Notes on UL approval
6
Commissioning
6.1
Alignment
6.2
Check the application conditions:
8023328.1HTH/2023-03-02 | SICK
Subject to change without notice
The device shall be supplied from an isolating transformer having a secondary overcur‐
rent protective device that complies with UL 248 to be installed in the field rated either:
a)
max 5 amps for voltages 0 ~ 20 V (0 ~ 28.3 V peak), or
b)
100 / Vp for voltages of 20 ~ 30 V (28.3 ~ 42.4 V peak).
Alternatively, they can be supplied from a Class 2 power supply.
UL Environmental Rating: Enclosure type 1
Alignment
Figure 2: Alignment
Sensing range
Check the application conditions: Adjust the sensing range and distance to the object
or background and the remission capability of the object according to the correspond‐
ing diagram [see
table
3].
1
1
2
2
3
2
2
4
0
(0.08)
(0.16)
(0.24)
Sensing range
1
Sensing range on white, 90 % remission
2
Sensing range on gray, 18 % remission
3
Sensing range on black, 6 % remission
Figure 4: Sensing range 8 mm
Figure 3: Alignment 2
8
9
8
9
8
9
6
8
10
(0.31)
(0.39)
Distance in mm (inch)
Sensing range typ. max.
O P E R A T I N G I N S T R U C T I O N | GTB2 Flat
OPERATING INSTRUCTION
320
650
en