Télécharger Imprimer la page

Airzone ZBS Serie Mode D'emploi page 13

Publicité

Les langues disponibles

Les langues disponibles

Battery replacement
The Airzone Think Controller will display a battery alert on its screen when the batteries of the radio interfaces are low.
To replace the battery, please remove the controller from its back plate and then replace the battery (CR2450).
EN
EN
FR
IT
PT
DE
Important: We recommend the use of top-brand batteries. Using low-quality batteries may reduce the duration of use.
ADVANCED USE OF THE THINK CONTROLLER
Setting Parameters
Press the Setting Menu icon to access the parameters.
Operation Mode. This parameter is only available when the controller is configured as main, the available modes are:
Cool. The conditioning unit will start a cooling cycle any time that any zone is in cool demand (T
It enables to activate the heat supply function.
Note: The Supply Heat is only available for individual zone modules.
Heat. Enables the heating cycle whenever a zone is in heating demand (T
Auto. The Auto mode allows automatic switching between cool and heat, depending on the global demand.
Dry. In this mode, the air-conditioning unit will start a dehumidification cooling cycle any time that any zone is
under demand (T
Note: Dry mode decreases humidity in the room by entering the dehumidification cooling cycle.
Emergency Heat. This mode activates the Auxiliary Heat to provide heated air in case of a mechanical failure in the
system.
Note: This mode is only visible when the installation includes an auxiliary heating device.
User Mode. This parameter is only available when the controller is configured as main, the available modes are:
Comfort. Default and standard user mode. The desired set point temperature can be selected using the predefined
temperature ranges.
Eco. The range of available set point temperatures change for more efficient operation.
Night time. The system automatically changes the set point temperature 0.5˚ C/1˚ F every 30 minutes in up to 4
increments of 2˚ C/4˚ F in 2 hours. When cooling, the system increases the set point temperature; when heating,
the system decreases the set point temperature.
Unoccupied. This mode aims to short periods of absence. Avoids the temperature to surpass the established limit
temperature for cooling and heating mode, generating demand with a set point temperature previously
established by the installer (27˚ C / 81˚ F in cooling mode and 17.5˚ C / 63˚ F in heating mode by default) for
returning to the allowed values, as long as the zone is on.
14
< T
).
Set point
room
Set point
> T
).
Set point
room
< T
).
room

Publicité

loading