To suit your needs, there are 2 ways to wire the ADA HAWSK3 to this range hood: 120 VAC power cable entering the switch box and
120 VAC power cable entering the range hood. Please follow the instruction for the appropriate method closely (on pages 2 and 3) to
ensure wiring is performed correctly.
CAUTION
Only use switches included in HAWSK3 ADA kit. Only
use wires suitable for at least 90oC (194oF).
NOTE:
Do not use the green screw and the ADA wire harness
included in HAWSK3 ADA kit.
120 VAC
POWER CABLE ENTERING THE SWITCH BOX
Install 2 included rocker switches at a convenient place for the
user. Feed the switch box with 120 VAC house wiring and use two
14/2 cable to wire it to the range hood (see diagram below).
120 VAC
LINE IN
WHITE
COM
BLACK
GROUND
Motor speed
selection switch
NO. 2
14/2 CABLE
TO HOOD
NOTES: 1.
Allow enough length of both 14/2 cables to perform the
RED, the BLUE and the BLACK wire connections in
the top right side of right blower scroll (shown next
page).
2. Use appropriate wire nuts for all connections.
Insert both 14/2 cable coming from switches in the hood through
an UL approved wire clamp. With a short ground wire (not
provided), connect all ground wires together as shown below.
Connect the other end of the short ground wire to the GREEN
ground screw.
Connect WHITE wire from no. 2 14/2 cable to WHITE wire from
range hood wiring.
Run BLACK wire from no. 2 14/2 cable along with BLACK and
WHITE wires from no. 1 14/2 cable to top right side of right
blower scroll. See next page for continuation.
2
NO. 2
14/2 CABLE
GROUND
BLACK
motor switch
light switch
NO. 1
14/2 CABLE
TO HOOD
3
TO TOP RIGHT SIDE
OF RIGHT SCROLL
MOTOR
GROUND
WIRE
1
NO. 1
14/2 CABLE
Motor speed
selection
switch
(3-way)
120 VAC
Install 2 included rocker switches at a convenient place for the user.
Use two 14/2 cable to wire it to the range hood (see diagram below).
COM
On/Off
Motor speed
selection switch
On/Off
NOTES: 1.
2. Use appropriate wire nuts for all connections.
Insert both 14/2 cable coming from switches in the hood through
an UL approved wire clamp. Insert 120 VAC house wiring in the
hood through another UL approved wire clamp. With a short
ground wire (not provided), connect all ground wires together as
shown below. Connect the other end of the short ground wire to
the GREEN ground screw.
Connect BLACK wire from no. 2 14/2 cable to BLACK wire from
120 VAC house wiring.
Run WHITE wire from no. 2 14/2 cable to top of right blower
scroll.
Connect WHITE wire from 120 VAC house wiring to range hood
WHITE wire.
Run BLACK and WHITE wires from no. 1 14/2 cable to top of
right blower scroll. See next page for continuation.
120 VAC
HOUSE WIRING
2
HIGH
LOW
OFF - ON
POWER CABLE ENTERING THE HOOD
BLACK
WHITE
BLACK
WHITE
GROUND
NO. 1
NO. 2
14/2 CABLE
14/2 CABLE
TO HOOD
TO HOOD
Allow enough length of both 14/2 cables to perform the
RED, the BLUE and the BLACK wire connections in
the top right side of right blower scroll (shown next
page).
4
3
TO TOP RIGHT SIDE
OF RIGHT SCROLL
2
NO. 2
14/2 CABLE
14/2 CABLE
ON/OFF
Motor switch
ON/OFF
Light switch
On/Off
motor switch
On/Off
light switch
5
TO TOP RIGHT SIDE
OF RIGHT SCROLL
MOTOR
GROUND
WIRE
1
NO. 1