7/ EVERYDAY MAINTENANCE
Your EuroCave cabinet is a tried and tested appliance.
Maintenance operations to be carried out approximately once a year
• Unplug and unload the appliance.
• Clean the water drain at the bottom of the wine cabinet. Pay attention that
nothing is blocking this drain.
• Regularly vacuum the condenser at the back of the appliance.
• Clean the inside of the compartments with water and a gentle cleaning product.
• Rinse thoroughly.
• Dry it with a soft rag.
• Replace the active charcoal filter in the breather hole at the top of your cabinet.
• Remove the charcoal filter manually. It is available from your usual retailer
It must be replaced by an original manufacturer's part.
• Check that the seals are in good condition. It is often necessary to clean the door
seal. Using unsuitable cleaning products can cause premature ageing of the seals.
Certain rules must therefore be followed: whenever you clean the seal, always
rinse off any cleaning product with clear water. All traces of cleaning product
must be removed from the seal. EuroCave only recommends using a mild soapy
solution. If this proves insufficient, it is possible to occasionally use an ethanol-
based solution, provided that the concentration used is less than 10% and that
the seal is then rinsed thoroughly with clear water.
Caring for glass elements:
• To clean the glass elements of your cabinet, use a non-abrasive soft cloth which has had a suitable glass cleaning
product applied to it.
Regular monitoring of your cabinet and reporting any faults to your retailer will ensure that your appliance
provides you with many years of faithful service.
34
GB
8/ OPERATING FAULTS
Possible incidents
Causes
The inner temperature is above
The
pictogram is displaying
4°C compare to the setting
temperature.
Operating fault
The
pictogram is still displaying
even though I have taken the
corrective actions above
The level of relative humidity
The
pictogram is flashing
has been < 50 % for over 72 hrs
The appliance cannot lower the level
of humidity to the desired value
Charcoal filter alarm
The
pictogram is displaying
Temperature sensor fault alarm
The
pictogram is displaying
Minimum duration of guarantee offered by the manufacturer: 3 years parts.
If your appliance does not seem to be working correctly, contact your EuroCave retailer.
9/ TECHNICAL FEATURES AND ENERGY DATA
9/ TECHNICAL FEATURES AND ENERGY DATA
LA PREMIERE
Height
1
Width
Depth
mm
mm
mm
1 temperature
V-LAPREMIERE-L
1825
680
690
V-LAPREMIERE-M
1480
680
690
V-LAPREMIERE-S
960
680
690
Multi-temperatures
S-LAPREMIERE-L
1825
680
715
Control accuracy: +/- 1°C (2°F), display accuracy: +/- 1°C (2°F).
1
Height including the top hinges and the feet, adjusted to mid-height.
2
Depth including the separator at the back of the cabinet for air ventilation. Handle not included.
According to delegated regulation (EU) 2019/2016 of the European Commission, access energy data about our appliances on the EPREL database by
scanning the QR code visible on your appliance's energy label.
The use of glass doors can alter your wine cabinet's performance in some extreme temperature conditions.
Corrective actions
Check that the door is correctly closed.
Check the condition of the door seal.
If you placed a large amount of bottles in your cabinet in the last few hours,
wait a while then check again. If the alarm is still displaying, contact your
EuroCave retailer.
Unplug the cabinet and contact your EuroCave retailer.
• Pour a glass of water into the duct of the tray (see chapter 7, § IV).
• In order to know how often to add water, count the number of days
separating the 1st day you added water and the day when the pictogram
was displayed
After a few hours, the pictogram will disappear.
• Empty the cabinet, remove the humidity cartridge and clean the tray.
• Remove the black drainage tube placed at the bottom of the cabinet. The
humidity will be directly discharged out of the appliance.
Call the EuroCave retailer if the problem persists despite having carried out
these different operations.
Replace the charcoal filter (see chapter 4).
Contact your EuroCave retailer.
2
Weight when empty
Recommended temperature range
Glass door (Kg)
Solid door (Kg)
Min T°(°C / °F) - Max T° (°C / °F)
Glass
92
78
0-30 / 32-86
79
68
0-30 / 32-86
56
49
0-30 / 32-86
92
78
12-30 / 54-86
Solid door
0-35 / 32-95
0-35 / 32-95
0-35 / 32-95
12-30 / 54-86
35