Supply
Model
mode
THREE
DTSU666
PHASE
CABUR
CODE:
EVDTSU6663PH
Meter configuration parameters
Parameter type
Code
(only for 3-phase model))
Serial configuration
Baud Rate
Address ModBus
1.2.1 1-phase meter configuration
The 1-phase meter configuration is performed through its ModBus interface.
In alternative the meter can be configured by means of its frontal button:
• switch the device on simply connecting it to the 1-phase power supply
• push the frontal button for at least 5 s
• during this time the display values rotate in a fast sequence
• release the button
• wait for the protocol indication to appear ("ModBus should appear)
• push the button once: the display shows the serial interface parameters. Select 8n1 = 8
bits, no parity, 1 stop bit
wait for the new display indication (the ModBus address), this happens automatically,
no needed actionsù
• When the ModBus address configuration page appears, push the configuration button
in order to have address = 2 (it is sufficient pushing the button twice, in case the value
is overpassed it is necessary to increase the address value up to its wrap-up value and
restart from 1)
February 2023
Description
3-phase
digital
energy
meter
RS-485
Modbus
Parameter value
701
8 bits, no parity, 1 stop bit
9600bps
2
Picture
Connection
Notes
The code is used to unblock
protected
default code value is 701)
-
-
-
scheme
accesses
(the
5