Mod Ports Card Type Model Serial No.
---+-----+--------------------------------------+--------------+--------------
1 24 24-Port 40GE/12-Port 100GE C9600-LC-24C CAT2252L0PR
2 48 48-Port 10GE / 25GE C9600-LC-48YL CAT2334L0BA
3 0 Supervisor 1 Module C9600-SUP-1 CAT2340L3Y5
5 48 48-Port 10GE / 25GE C9600-LC-48YL CAT2337L509
Mod MAC addresses Hw Fw Sw Status
---+--------------------------------+----+------------+------------------+--------
1 70B3.175A.8100 to 70B3.175A.817F 1.0 17.3.1r[FC2] 17.03.01 ok
2 10B3.D652.9900 to 10B3.D652.997F 1.0 17.3.1r[FC2] 17.03.01 ok
3
7C21.0E5D.0400 to 7C21.0E5D.047F 1.0
5 4C71.0D7C.8400 to 4C71.0D7C.847F 1.0 17.3.1r[FC2] 17.03.01 ok
Mod Redundancy Role Operating Redundancy Mode Configured Redundancy Mode
---+-------------------+-------------------------+---------------------------
3 Standby
Switch Number 2
**snip**
Remplacement d'un superviseur de C9600 Quad-Sup
StackWise-Virtual
Dans cet exemple, vous envisagez une configuration C9600 Quad Sup stackwise-Virtual (deux
superviseurs dans chaque châssis), dans laquelle un superviseur est défectueux et doit être
remplacé. Le SVL s'exécute en mode de démarrage « Install ».
Remplacer et vérifier
Sortir le superviseur défectueux
sso
Si le superviseur à remplacer est un superviseur actif global (Sw-1 Slot 3
dans l'image ci-dessus), effectuez un basculement afin que le superviseur
actif global (Sw-2 Slot 3 dans l'image ci-dessus) prenne le relais comme
étant actif. Patientez jusqu'à ce qu'une nouvelle mise en veille globale et une
SSO soient terminées. (Dans ce cas, le logement 4 du commutateur 1
deviendra le nouveau Global Standby).
Si le superviseur à remplacer est un superviseur de secours global (Sw-2
Slot 3 dans l'image illustrée), retirez le superviseur. Patientez jusqu'à ce
qu'une nouvelle mise en veille globale et une SSO soient terminées. (Dans
ce cas, le logement 4 du commutateur 2 deviendra le nouveau Global
17.3.1r[FC2]
17.03.01
sso
ok