9 Solving malfunctions and problems
− When working on the equipment, the equipment must be voltage-free;
− Electrical installation must be carried out by an electrically skilled person.
Signaling
Problem
LED unlit
No power supply
No compressed
No compressed air
air on the
from the Blowflex
Blowflex
outflow opening /
nozzle
No compressed air
from the Blowflex
outflow opening /
nozzle
Not enough
No discharge
compressed air
Poor discharge
No discharge
No discharge
Poor discharge
Poor discharge
Table 3: malfunctions

10 Repairs

The Blowflex can only be repaired by Simco Ion.
In case of problems and or questions, please contact Simco Ion or a Simco Ion representative
in your region.
BlowflexEasy_UM_9752161610_NL_D_GB_F_1.3
What this means
Defective power supply
Power supply not connected
Power supply incorrectly
connected
Compressed air is not connected Connect the compressed air
Any compressed air valve in the
compressed air connection does
not allow air to pass through. The
Blowflex does not have a
compressed air valve.
Compressed air pressure set too
low
Blowflex ionizer is contaminated
by moist air or air contaminated
with oil.
Ionization component in Blowflex
defective or worn out
Compressed air pressure set too
low
Ionization component in the
Blowflex worn out
Blowflex ionizer is contaminated
by moist air or air contaminated
with oil.
Ionization component in Blowflex
defective or worn out
Blowflex ionizer is contaminated
by moist air or air contaminated
with oil.
Ionization component in the
Blowflex worn out
Solution
Connect power supply See H5
& H6
see H5 & H6
Connect the compressed air
see H5 & H6
Increase the pressure H5 & H6
Clean the Blowflex ionizer with
clean dry clean air. If this
doesn't work, have Blowflex
repaired See H10
Repair the Blowflex
See H10
Increase the pressure
See H6
Repair the Blowflex
See H10
Clean the Blowflex ionizer with
clean dry clean air. If this
doesn't work, have Blowflex
repaired See H10
Repair the Blowflex
See H10
Clean the Blowflex ionizer with
clean dry clean air. If this
doesn't work, have Blowflex
repaired See H10
Repair the Blowflex
See H10