5.2 General

Determine the optimal location where the ionizer with the power supply and the compressed air
hose will be used.
The compressed air hose and the power cable can be tied together with suitable materials.
Use a standard Simco Ion Device cable as a power cable (see accessories) or make your own
connection cable with an M12 connector (see section 5.4)

5.3 Power and compressed air supply

− Make sure that the Blowflex Easy is supplied with clean, moisture and oil-free compressed
air.
− Make sure that the compressed air connection and the 24V power supply are within reach of
the connection hose and connection cable. Both the hose and the cable must not be able to
come under tension during use.
− Screw the power cable with the M12 connector hand tight to the ionizer.
− Connect the other side of the power cable to the 24V power supply.
See connection data of the cable for mounting on your own 24V system.
− Connect the compressed air hose to the G ¼" compressed air connection of the ionistator.
− Connect the other end of the compressed air hose to the compressed air connection with
suitable materials. Use a pressure regulating valve with filter to regulate the compressed air
to the desired pressure.
− Refer to the manual of the 24V power supply for connecting the power supply.