User manual
4
Preparation
•
Compare the specifications of all used devices to ensure compatibility.
•
Check the scope of delivery for completeness and integrity.
5
Installation
•
Let open cable ends ONLY assemble by experienced
electrician.
•
Cut off power supply before any work on the product,
switch off safety fuse and secure against reconnection.
•
Assure and check the absence of voltage before any
work on the product.
The power cord used should have a minimum cross section of 1.0 mm². The
following connections are made to the terminal block of the product.
1. Connect your lamps (LOAD) like shown.
If using several lamps, they must be wired in parallel.
Power cables are installable sidewise or from above.
2.
Fix all wire connections using a screwdriver.
3.
Insulate the connection against contact and moisture.
The earth wire will not be connected.
5.1
Installation without separate light switch
Fig. 7: Installation without separate light switch
17
Risk of electric shock