APPLIANCE EMBEDDING INSTRUCTIONS.
To limit the heating of the walls composing the casing of the fireplace to be built to 65K (K = degrees Celsius above room
-
temperature), and for the appliance to operate properly, the principles shown in the diagram below should be followed.
Respect the minimum embedding and convection air circuit dimensions (size of the intake for the "air to be heated" and
-
"hot air" outlet size).
-
The indicated minimum embedding dimensions guarantee access to operating controls, sufficient space for the moving
parts, access and removal of parts that may need to be replaced.
Hot air outlet size: 12 dm²
80 mm
Fresh air intake size: 4 dm²
50 mm thick rock wool, max conductivity 0.04W/m°C
with aluminium side facing the insert
concrete
fireplace walls and floor
Rédacteur FL , le 17/02/2020
OPT. 700 Insert
80 mm
référence P677175
flue key
Min 500
mm
30 mm
400 mm