TYPE OF PROBLEM
Sprayer does not run at all
Digital display shows E=06
Control board status light blinks
6 times repeatedly
Sprayer does not run at all
Digital display shows E=09
Control board status light blinks
9 times repeatedly
38
WHAT TO CHECK
If check is OK, go to next check
Allow sprayer to cool. If sprayer runs
when cool, correct cause of
overheating. Keep sprayer in cooler
location with good ventilation. Make
sure motor air intake is not blocked.
If sprayer still does not run, follow
Step 1.
Check the connections. Control
is not receiving a motor position
sensor signal
Cleanup / Nettoyage / Limpieza
WHAT TO DO
When check is not OK, refer to this column
NOTE: Motor must be cooled down for the test.
1.
Check thermal device connector (yellow wires)
at control board.
2.
Disconnect thermal device connector from control
board socket. Make sure contacts are clean and
secure.
3.
Measure resistance of the thermal device. If reading
is not correct, replace motor.
Check Motor Thermal Switch: Unplug thermal
wires. Set meter to ohms. Meter should read the
proper resistance for each model (see table below).
4.
Quick test for Ultras
-
ti13140a
Resistance Table:
Ironman 300E
695
795
1095
1595
5.
Reconnect thermal device connector to control
board socket. Connect power, turn sprayer ON and
control knob 1/2 turn clockwise. If sprayer does not
run, replace control board.
1.
Turn power OFF.
2.
Disconnect m-p sensor and inspect for damage.
3.
Reconnect sensor.
4.
Turn power ON. If error continues, replace board.
8.2k ohms
0 ohms
2k ohms
3.9k ohms
6.2k ohms
311287E