GENERAL DESCRIPTION
The RWX73F is a 2-way multi-function supervised transmitter with two separate
channels that combines Magnetic/Door contact with two additional inputs (one universal and the
other universal or shutter). The RWX73F has two reed switches for protection against opening
doors and windows, and against any attempt to tamper with the detector using large magnets.
The RWX73F operates with RISCO Group 2-Way wireless systems.
MAIN FEATURES
• Communication: Bi-directional
• Range: Up to 300 m (1,000 ft.) range line of sight
• Supervision: Up to 255 minutes
• Selective Zone termination : NO, NC, DEOL
• Selective Zone response: 10 / 500ms
• Tamper protection: Back + cover
• Anti-sabotage tamper protection
• 2 channels recognized as separate zones in the system
OPERATING CHANNELS
RWX73F supports 2 separate channels, each with unique serial number (Fig.7).
Channel Report Events From
1
Magnetic Contact +
Input 1 (IN1)
2
Input 2 (IN2)
INSTALLATION
Step 1: Transmitter Receiver Communication Setup
The X73F must identify itself to the system's receiver by writing its coded message into the
receiver's address memory. The receiver must identify each channel separately, as defined by DIP
switch 1. This registration for each channel is performed either by entering the RWX73F's 11-digit
serial code number or by performing the following RF allocation steps:
1. Remove the front cover (Fig 1), and then set the main unit to Learn mode.
2. Remove battery from the insulation material and reinsert it into the transmitter, paying
attention to the polarity (Fig. 2).
3. For channel 1 set Dip switch 1 to OFF.
4. Send a write message by pressing the front tamper switch (don't detach
back bracket) for at least 3 seconds until panel recognition displays (Fig. 2).
NOTE: After registration or after exiting the control panel's Programming mode, the magnet
will receive 2-Way data from the control panel for approx. 30 seconds. During this time period,
the magnet will not respond to any trigger but only to tamper activation. At the termination of
this time period, the magnet will revert to normal operation.
5. For channel 2, wait 30 seconds (after channel 1 registration) and repeat step 4 with DIP switch 1
in the ON position.
NOTE: Wait at least 1 minute before closing the front cover.
Step 2: Input Wiring
Use the diagrams for appropriate input termination wiring. For DEOL termination connect two
10K Ohm resistors (supplied). See Figure 8.
LED INDICATION
• Upon successful learning: short flash
• Normal operation: brief light upon
•
Functionality
Universal
Universal / Shutter
4
sequence
transmission
Low battery: short flash sequence
during transmission
Restore Message
Follow Event Restore
Follow Event Restore / Immediate