6.  Start-up
Pilot light
Evaporator-fan active
One or more compressors active
6.2 Control panel operations
IMPORTANT: these operations are also possible from the App and do not correspond to the parameters.
6.2.1 Turn the packaged unit on and off
Turn on: press and hold the
l
appears on the display. Refer to the complete manual on the MY I.D. App.
Turn off: and press and hold the
l
parameter /t1 alternate on the display. Refer to the complete manual on the MY I.D. App.
Note: the ambient temperature must be below 32°C to be able to carry out the first start-up.
6.2.2 Switch the coldroom light on and off
Switch on: press and hold the
l
the display.
Switch off: press and hold the
l
display goes off.
6.2.3 Set the temperature setpoint value
Press and hold the
l
on the display.
Briefly press the
l
current temperature setpoint value.
Press the
and
l
Briefly press the
l
parameter /t1 appears on the display.Refer to the complete manual on the MY I.D. App.
6.2.4 Controlling the manual defrost cycle
Press and hold the
l
is with hot gas, the compressor pilot light also lights up.
6.2.5 View and reset the active alarms
Flashing text
indicates the presence of triggered alarms.
Press the
button briefly. The display shows the code of the last triggered alarm.
l
Press the
and
l
Press and hold the
l
manual reset. no aLr appears on the display.
Exiting from a menu
Briefly press the
l
112
Steady on
button for 3 seconds. The value of the quantity set in parameter /t1
button for 3 seconds. OFF and the value of the variable set in
button for 3 seconds and release. The coldroom pilot light lights up on
button for 3 seconds and release. The coldroom pilot light on the
button for 3 seconds and release. SEt and the temperature setpoint value alternate
button to be able to modify the temperature setpoint value. The display shows the
buttons to select the desired temperature setpoint value.
button to save the new temperature setpoint value. The value of the quantity set in
button for 6 seconds. The defrost pilot light lights up on the display. If the defrost
buttons to view the codes of the triggered alarms.
button for 3 seconds and release to reset the triggered alarms that require a
button at least once to return to the desired position.
BEST W R290
Instruction manual
Flashing on
-
Compressor not enabled at
start-up due to:
Safety device times
l
Open door
l
Start-up delay
l
v. 00 | 9600-0033
© 2020 RIVACOLD srl
Rev.
 | 