TECHNICAL DATA
Operating voltage:
Current:
Micro switch:
Ambient temperature:
Bolt throw:
Backsets:
Forend:
Trigger bolt:
Functions selected on
the lock case:
Indications:
Door clearance:
Connection cable:
Striker plates:
!
Not to be installed in doors with seal force.
!
Bolt and trigger bolt have to be lubricated during installation and when necessary.
!
Not suitable for use in fi re door.
STANDARDS
EN12209
4
12 - 24 V DC -10% / +15% STAB
12 V
Max. 550 mA
Normal 240 mA
24 V
Max. 270 mA
Normal 110 mA
max. 0.4 A 30 V AC / V DC resist. max. 10 W
-20° - +60°C
14.5 mm
25, 30, 35 mm
25 mm
Symmetrical
Electrical function
- fail locked
- fail unlocked
Deadlocking status of double action bolt
3 - 5 mm (Between forend and strike)
EA211 (6 m), EA221 (10m) 9 x 0.14 mm2
EA307, EA308, 4613, 4614, 443608 (for swinging doors)
Mechanical strength
R
ENGLISH