Troubleshooting - Emerson RAH ECO CF915TM60BS00 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE
TROUBLESHOOTING YOUR FAN.
TROUBLE
TROUBLE
1. Fan will not start. 1. Fuse or circuit breaker blown.
2. Loose power line connections to the fan.
3. The remote control transmitter battery needs
replacement.
4. Fan/Light remote control is OFF.
5. Remote is not programmed.
2. Fan sounds
1. Blades not attached to fan.
noisy.
2. Screws securing fan motor to motor
hub are loose.
3. Screws holding blades to motor are loose.
4. Glass globe loose.
5. Hanger bracket and/or ceiling outlet box is not
securely fastened.
3. Fan wobbles
1. Screws securing fan blades to motor are loose. 1. Check to be sure screws which attach the fan blade to the
excessively.
2. Set screw in motor coupler is loose.
3. Fan blades out of balance.
4. Hanger bracket and/or ceiling outlet box is not
securely fastened.
5. Set screw in hanger ball/downrod assembly is
loose.
6. Screws securing fan motor to the motor hub
are loose.
4. Light fixture will
1. Loose electrical connectors.
not illuminate.

14. Troubleshooting

!
PROBABLE CAUSE
PROBABLE CAUSE
WARNING
1. Check main and branch circuit fuses or circuit breakers.
Make sure main power is turned OFF.
2. Check line power connections to fan.
3. Check that the remote transmitter battery is in good
condition; the blue indicator will illuminate when the key
pad buttons are depressed.
4. Turn ON Fan/Light remote control.
5. Program the remote and receiver per the Owner's
Manual instructions.
1. Attach blades to fan before operating.
Make sure main power is turned OFF.
2. Check to make sure the screws which attach the blades to
the motor are tight.
3. Tighten screws securely.
4. Tighten the glass globe securely.
5. Tighten the hanger bracket screws to the outlet box,
and/or secure outlet box.
motor are tight.
2. Raise coupler cover and tighten the set screw securely.
3. Interchanging an adjacent (side by-side) blade pair can
redistribute the weight and result in smoother operation.
Or use supplied balancing kit to balance blades.
4. Tighten the hanger bracket screws to the outlet box,
and/or secure outlet box.
5. Tighten the set screw in the hanger ball/downrod
assembly.
6. Check to be sure the screws which attach the
motor to the motor hub are tight.
1. Shut off the branch circuit electricity at the fuse box or
breaker panel and check the electrical connectors for
proper installation.
28
SUGGESTED REMEDY
SUGGESTED REMEDY
WARNING
!
WARNING
!
U.L. Model No.: CF915

Publicité

Table des Matières
loading

Table des Matières