The ATS output
The walk test can be programmed through the control panel by
activating an output in the DGP range.
Memory location map
Every PID device has its own characteristics concerning
related I/O lines or certain functionality of the device.
A total of 16 memory locations are reserved to configure the
PID devices. Only the first nine normally are user configurable.
This depends on the functionality of the particular device.
For the AD111 internal PID interface only memory location 6
matters.
On memory location 6 the ATS-style output can be configured.
Memory location map for AD111
Location
Function Decimal
values
6
ATS-style
0
output [1]
[1] ATS-style output
The output can be used to enable/disable the Alarm LED or
Walk Test LED on the detector. ATS output and zone
numbering are equivalent.
The default output number of the device equals the input
number when memory location 6 is set to 0 (default).
Please refer to the PID DGP manual for PID address settings
and zone numbering.
The output number on the AD111 can also be changed within
the DGP output range (e.g. DGP 1 output 17-32). If the output
of this device or all the outputs of similar devices on the same
DGP need to be programmed on for example output 32, simply
program memory location 6 of all those I/O devices to 32.
Specifications
Bus protocol
Bus voltage
External power supply
Current consumption from bus
Unit load for DGP
Address range
Current O/C output
Category
Device type
P/N 149957999-4 (ML) • REV E • ISS 14DEC20
Binary values
0000 0000
ATS output number that controls
the AD011/AD111 output by
means of "output on" / "output off"
[1].
Carrier Fire & Security Point ID
12 or 24 V
9 to 13.8 V
330 µA ±10%
1
0 to 255
100 µA max.
I/O
T2
Regulatory information
Manufacturer
PLACED ON THE MARKET BY:
Carrier Fire & Security Americas Corporation Inc.
13995 Pasteur Blvd
Palm Beach Gardens, FL 33418, USA
AUTHORIZED EU REPRESENTATIVE:
Carrier Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
THESE PRODUCTS ARE INTENDED FOR SALE
and disclaimers
TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. CARRIER FIRE &
SECURITY CANNOT PROVIDE ANY
ASSURANCE THAT ANY PERSON OR ENTITY
BUYING ITS PRODUCTS, INCLUDING ANY
"AUTHORIZED DEALER" OR "AUTHORIZED
RESELLER", IS PROPERLY TRAINED OR
EXPERIENCED TO CORRECTLY INSTALL FIRE
AND SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/
Certification
Carrier Fire & Security hereby declares that this
device is in compliance with the applicable
requirements and provisions of the Directive
2014/30/EU and/or 2014/35/EU. For more
information see www.firesecurityproducts.com or
www.aritech.com.
Product may contain substances that are also
REACH
Candidate List substances in a concentration
above 0.1% w/w, per the most recently published
Candidate List found at ECHA Web site.
Safe use information can be found at
https://firesecurityproducts.com/en/content/intrusi
on-intro
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
www.recyclethis.info
Contact information
www.firesecurityproducts.com or www.aritech.com
For customer support, see www.firesecurityproducts.com
FR: Instructions d'installation
Description
Le DGP AD111 est une interface interne conçue pour les
systèmes de détection adressables. Elle assure la liaison
entre un détecteur générique équipé de contacts secs d'alarme
et d'autoprotection et le DGP adressable ATS1290 Advisor
MASTER. Cette interface est équipée de deux entrées
destinées à être raccordées au relais d'alarme et à
l'interrupteur d'autoprotection d'un détecteur, et d'une sortie
collecteur ouvert. Cette sortie pourra, par exemple, être utilisée
pour activer, ou désactiver, la LED d'alarme sur un détecteur
or scan the QR code.
3 / 8

Publicité

Table des Matières
loading

Table des Matières