STOPS

The gate can be stopped by stops secured to the floor so that travel is defined from opening to closing�
STOPS

PRELIMINARY CHECKS

Remember that the drive is designed to make the gate/door easier to use and will not solve problems as a result of defective or poorly performed
installation or lack of maintenance�
Check that:
- gate's running track is straight and horizontal and that the wheels are strong enough to take the weight of the gate: once released, the leaf
should be perfectly still and should not open or close;
- there is a slideway at the top of the leaf to avoid vertical or lateral oscillations during manoeuvres;
- leaf movement is even and there is no friction concentrated in any part of its travel;
- the existing structure has the necessary durability and stability requirements, specifically screws, bolts and rods that must be suitably secured;
- the leaf surface is free of protrusions and sharp edges, without signs of abnormal wear, rust, breaks or cracks in frame elements;
- there are mechanical stops secured to the ground in opening and closing;
- the stated temperature range is compatible with the site in which the automated system is due to be installed;
- any thresholds in the passageway and greater than 5mm are visible, indicated or well-formed�
If the frame and gate do not meet the indicated specifications, do not install the drive: have the frame adjusted as necessary by qualified personnel�

Important:

- Eliminate the gate lock or any other manual lock device�
- This product cannot be installed on leaves that incorporate doors�
- The pair of photocells supplied in the kit must be installed and tested at the end of installation�
- Make sure safety gaps < 8 mm in upper guides or apply rubber protections�
- If there are slots in the leaf or gate, install a protective mesh whose dimensions depend on the distance between the
leaf and gate, according to that indicated in the following table
The distance between
the gate and leaf
≤ 120mm
≤ 300mm
≤ 500mm
850mm
Mesh dimensions
d ≤18�5mm
18�5mm < d ≤ 29mm
29mm < d ≤ 44mm
d > 44mm
C
C
d
STOPS