Important: Always perform a "walk around" test to verify coverage before using a wireless system during a speech or perfor­
mance. Experiment with placement to find the optimum location.

Requirements Checklist

Make sure your equipment meets these requirements before installing the system:
Use shielded Cat 5e or higher Ethernet cables.
Use balanced XLR cables for analog input/output.
Use Gigabit DHCP router to connect multiple access points in the same installation. Ensure it meets the following require­
ments:
Gigabit ports
Provides Class 0 PoE with at least 6.5 W
Quality of Service (QoS) with 4 queues
Diffserv (DSCP) QoS with strict priority
If the router features Energy Efficient Ethernet (or Green Ethernet), ensure it is disabled from the ports dedicated for
the system
Recommended: A managed switch to provide detailed information about the operation of each network link (port
speed, error counters, bandwidth used, etc.)
Limiting cable runs to ≤100 meters between devices.
Use same firmware version for all devices in your system.
Ensure MXCW components and the computer are on the same network and set to the same subnet.