This chapter describes the most common problems related using the appliance. If the
problems cannot be resolved with the information below, please contact the Authorised
Service Centre in your country.
Problem
The appliance does not go on.
The plate temperature LED (18)
Smoke comes out of the
appliance when it is switched on
Impurities come out of the plate
of the new iron.
Drops of water come out of the
plate.
The appliance does not produce
steam.
The plate is dirty.
Steam comes out from the boiler
safety cap (1) while ironing.

TROUBLESHOOTING

Possible cause
The household appliance is not on.
Normal procedure.
This is absolutely normal and is
due to the expansion of the plastic
material.
This is perfectly normal in a new
iron.
The iron temperature adjustment
knob (12) is set to a temperature that
is too low for steam ironing.
The appliance is not on.
The steam button (11) is not being
pressed.
and the no water LED (3) is on.
The steam adjustment knob (4) is
set to the minimum.
The impurities or chemical
substances found in the water
have deposited on the plate.
You are ironing at a temperature
that is too high.
The boiler safety cap (1) may
have not bee closed correctly or
water may have leaked while being
topped-up.
Solution
Verify that the appliance is connected
correctly to the power cable and the ON
buttons of the iron (6) and boiler (7) are
pressed.
The switching ON and OFF of the LED
indicates the heating phase of the iron. The
reached and you can start ironing.
This no longer occurs after a while.
These particles are completely harmless
and will disappear after the iron is used a
few times.
Set the knob to a suitable temperature
for steam ironing (refer to the "IRONING"
chapter).
Press the ON buttons of the iron (6) and
the boiler (7).
you iron.
Fill the boiler (refer to the "Filling the
boiler when hot" chapter).
Set the steam adjustment knob (4) (refer
to the "IRONING" chapter).
Wait for the plate to cool down and clean
it with a damp cloth.
Wait for the plate to cool down and clean
it with a damp cloth.
Switch the appliance OFF and let it cool
down. Remove the boiler safety cap (1),
dry the water around the top-up opening
and tighten the cap. The appliance can
then be switched back on.