12
b) Presetting the routing depth
10.6
10.1
10.2
10.3
10.4
– Pull the depth stop [10.4] upwards until the
indicator [10.2] reaches the required routing
depth.
– Clamp the depth stop in this position using the
clamp lever [10.3].
– Unscrew the rotary knob [10.1]. The machine is
now in starting position.
– If necessary, you can readjust the routing depth
by turning the adjusting wheel [10.4]. Each mark
represents a routing depth of 0.004" (0.1 mm).
One complete turn of the wheel is ~1/16" (1 mm).
Notes:
The dial ring [10.5] can be turned separately to
the "zero" setting.
The three marks [10.7] indicate the maximum
adjustment range of the adjusting wheel 3/4"
(20 mm)and the central position when aligned
with the edge [10.8].
Preliminary/Fine routing
11.1
11.2
10.5
9
6
8
7
8 0
7 0
6 0
5 0
4 0
10.8
3 0
2 0
1 0
0
10.7
C
Stop C has two stop limits with a height difference
of 1/16" (2 mm) . Routing to the depth preset with
stop C can be performed in two steps:
– Lower the router to the fi rst stop level [11.1] for
the preliminary routing step;
– Lower the router to the second stop level [11.2]
to complete the routing procedure.
This procedure enables rapid routing to a consider-
able depth while still achieving a good surface qual-
ity. The fi nal routing depth is defi ned by adjusting
the stop level [11.2].
Fine adjuster for edge trimming
The machine has a special fi ne adjuster for routing
tools with a bearing guide, which allows quick and
easy precision adjustment prior to rounding edges
and prevents offsets.
First of all, roughly preset the routing depth and
perform a test run. Then adjust the routing depth
more precisely:
– Open the clamping lever [13.2].
– Push the depth stop [13.3] against the fi xed stop
C [13.5].
– Clamp the depth stop using the eccenter [13.4]
on the stepped stop (turn clockwise).
– Close the clamping lever [13.2].
– Unscrew the rotary knob [13.1].
– Turn the adjusting wheel [13.6] to set the routing
depth more precisely.
The routing depth can be adjusted in both direc-
tions because the depth stop is connected to the
stepped stop.
– Tighten the rotary knob [13.1].
– Open the eccenter [13.4] (turn anticlockwise).
– Perform more test runs and make the appropri-
ate adjustments if necessary.