Franke FTU 3805 XS CYLINDRA E LED0 Mode D'emploi Et Installation page 10

Masquer les pouces Voir aussi pour FTU 3805 XS CYLINDRA E LED0:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
Fitting the hood body – Recirculation Version
• Detach the 2 brackets that can be seen inside the opening
on the top part of the hood canopy.
• Rest the Hood Canopy 1 on the Suction Unit 3, inserting it,
and fix it at the side using the 2 screws 12b.
• Position the directional grille 8 on the pipe and check that it
has been fitted properly.
• Fasten the directional grille 8 using the screws 12e
provided.
• Make sure that the Activated charcoal odour filter has been
fitted.
Electrical connection
• Connect the Hood to the Mains Power Supply, inserting a
bipolar switch with a contact aperture of at least 3 mm.
• Remove the filter and make sure that the Power cable has
been properly inserted into the Suction fan socket
• Take the control box inside the suction unit 3 and slot it
into the plastic support provided for it in the hood canopy
at the height of the controls.
• Pass an fix the wiring through with the Adhesive cable tie
already mounted.
• Fasten the Spotlights connector Lux.
• For the Recirculation Version, fit the Activated Charcoal
Odour Filter.
• Replace the metal grease filters.
EN