Solution tank filling
6.
Open the plug (21) and fill the tank (22) with a solution suitable for the work to be performed. Do not fill the solution tank
completely, leave few centimeters from the edge. Always follow the dilution instructions on the label of the chemical product
used to prepare the solution. The solution temperature must not exceed 104°F (40°C).
CAUTION!
Use only low-foam and non-flammable detergents, intended for automatic scrubber applications.
WARNING!
When using floor cleaning detergents, follow the instructions on the labels of the detergent bottles.
To handle floor cleaning detergents, wear suitable gloves and protections.
Adjustments
7.
Press the lever (40) and adjust the handlebar (2) to reach a comfortable position.
MACHINE START AND STOP
Starting the machine
1.
Prepare the machine as shown in the previous paragraph.
2.
Turn the function selection knob (31) to turn on the machine and select one of the programs according to the following table:
Position
Symbol
(32)
(33)
(34)
3.
Turn the solution flow control switch (36) to one of the following positions, according to the type of cleaning to be performed:
•
One drop: to scrub/clean floors which are not very dirty; in this condition the machine can work with an autonomy of 50
minutes (0.25 liters/min average).
•
Two drops: to scrub/clean floors which are quite or very dirty; in this condition the machine can work with an autonomy of
25 minutes (0.5 liters/min average).
4.
While keeping the hands on the handlebar (2), start the machine by pressing the enabling push-button (38) together with the
brush levers (39).
NOTE
If the green warning light (37) turns on, the machine is ready to be used. If the yellow or red warning light turns on, the
battery must be charged (see the procedure in Maintenance chapter).
Stopping the machine
5.
Release the brush levers (39) and the enabling push-button (38).
6.
Turn the function selection knob (31) to "0" to turn off the machine.
CAUTION!
In case of immediate necessity and to stop all machine functions, disconnect the battery connector (7).
Reset the machine functions by connecting again the connector.
Program
Scrubbing and drying.
Brush - vacuum system - solution flow activation
Scrubbing.
Brush - solution flow activation
Drying.
Brush - vacuum system activation
INSTRUCTION FOR USE
9099867000 - SC351
ENGLISH
11