pH value
electrical conductivity *
settleable solids **
total suspended solids *** < 50 mg/l
Hydrocarbons
Chloride
Sulphate
Calcium
Total hardness
Iron
Manganese
Copper
Active chloride
free of bad odours
* Maximum total 2000 μS/cm
** Test volume 1 l, settling time 30 min
*** no abrasive substances
Safety instructions
DANGER
– Do not use high pressure cleaners
when there has been an oil spill; move
the appliance to another spot and avoid
any sort of spark formation.
– Do not store, spill or use fuel in the vi-
cinity of open flames or appliances such
as ovens, boilers, water heaters, etc.
that have an ignition flame or can gen-
erate sparks.
– Keep even mildly inflammable objects
and materials away from the silencer (at
least 2 m).
– Do not start the engine without the si-
lencer; check, clean and replace, if re-
quired, the silencer at regular intervals.
– Do not use the engine in forest, bushes
or grassy areas without fitting a spark
receiver at the exhaust.
– Except for setting jobs, do not run the en-
gine when the air filter is removed or there
is no cover over the suction support.
22
6,5...9,5
Conductivity
fresh water
+1200 μS/cm
< 0,5 mg/l
< 20 mg/l
< 300 mg/l
< 240 mg/l
< 200 mg/l
< 28 °dH
< 50 °TH
< 500 ppm (mg
CaCO
/l)
3
< 0,5 mg/l
< 0,05 mg/l
< 2 mg/l
< 0,3 mg/l
– 3
EN
– Do not make any adjustments to the
regulator springs, regulator bars or oth-
er parts that can bring forth an increase
in the engine speed.
– Risk of burns! Do not touch hot silenc-
ers, cylinders or radiator ribs.
– Do not put hands or feet close to mov-
ing or rotating parts.
– Risk of poisoning! The appliance should
not be operated in closed rooms.
General
– Please follow the national rules and
regulations for fluid spray jets of the re-
spective country.
– Please follow the national rules and
regulations for accident prevention of
the respective country. Fluid spray jets
must be tested regularly and the results
of these tests must be documented in
writing.
– The heating appliance of the machine is
an ignition plant. All national laws and
regulations about heating systems must
also be followed.
High pressure hose
DANGER
Risk of injury!
– Only use original high-pressure hoses.
– The high-pressure hose and the injec-
tion system must be suitable for the
maximum operating pressure given in
the Technical Data.
– Avoid contact with chemicals.
– Check the high-pressure hose daily.
Do not use hoses with kinks.
Stop using the high-pressure hose if the
external wire layer is visible.
– Do not use the high-pressure hose any-
more if the winding is damaged.
– Lay the high-pressure hoses in such a
way that no vehicle can drive over it.
– Do not use high-pressure hoses that
have been driven over, kinked, pressed
or bent even if there is no externally vis-
ible damage.
– Store the high-pressure hoses in such a
way that they are not subject to any me-
chanical load.