6.3.4 S
I
IMPLIFIED
NSTALLATION
When performing duct connections to the furnace supply
duct, use metal ducts appropriately sized to support the
additional airflow produced by the unit.
Stale air exhaust ductwork:
Cut an opening into the furnace return duct not less than 10 feet (3.1 m) (A + B)
away from the furnace.
Connect this opening to the stale air intake port of the unit (as shown above).
Fresh air distribution ductwork:
Cut an opening into the furnace supply duct at least 18 inches (0.5 m) away from
the furnace.
Connect this opening to the fresh air distribution port of the unit (use metal ducts,
see illustration at right).
Make sure that the duct forms an elbow inside the furnace ductwork.
NOTE : For this type of installation, it is recommended, however, not essential, that the
furnace blower be synchronized with the unit.
6.3.5 S
I
IMPLIFIED
NSTALLATION
Stale air exhaust ductwork:
For this type of installation, the furnace must always be
synchronized with the unit. See section 7.
Cut an opening into the furnace return duct not less than 10 feet (3.1 m) (A + B)
away from the furnace.
Connect this opening to the stale air intake port of the unit.
Fresh air distribution ductwork:
Cut an opening into the furnace supply duct at least 18 inches (0.5 m) away from
the furnace.
Connect this opening to the fresh air distribution port of the unit (use metal ducts,
see illustration at right).
Make sure that the duct forms an elbow inside the furnace ductwork.
Make sure that both connections to the furnace return duct are at least 3 feet (1
m) apart (C).
6.4 I
E
NSTALLING THE
XTERIOR
Refer to illustration at right to connect the insulated duct to the hoods. An "Anti-Gust
Intake Hood" should be installed in regions where a lot of snow is expected to fall.
Make sure that both hoods are at least 18 inches above the
ground and that the intake hood is at least 6 feet (1.8  m)
away from any of the following:
Exhaust hood
Dryer exhaust, high efficiency furnace vent, central
vacuum vent
Gas meter exhaust, gas barbecue-grill
Any exhaust from a combustion source
Garbage bin and any other source of contamination
- R
/S
ETURN
UPPLY
CAUTION
- R
/R
ETURN
ETURN
CAUTION
H
OODS
WARNING
VH0132
VH0133
E
XHAUST
H
OOD
18"
(457
MM
(1.8
C
VD0028
9
18" (0.5
MINIMUM
A
A + B =
10' (3.1
B
A
T LEAST
3' (1
)
M
A + B =
6" ø
(152
)
MM
I
NTAKE
H
OOD
)
18"
6'
(457
)
MM
)
M
O
PTIONAL
T
DUCT LOCATION
APE AND DUCT TIE
AULKING
)
M
B
AT LEAST
)
M
A
AT LEAST
10' (3.1
)
M
6'
(1.8
)
M
18"
(457
)
MM