For the Installer

9. BALANCING THE UNIT

P
REPARATION
Follow these steps to ensure accurate measurements:
Seal all the ductwork with tape. Close all windows and doors.
Turn off all exhaust devices such as range hood, dryer and bathroom fans.
Make sure the balancing dampers are fully open.
If the installation is in any way connected to the ductwork of the cold air return of a furnace/air handler, make sure that the furnace/
air handler blower is ON. If not, leave furnace/air handler blower OFF.
If the outside temperature is below 0°C/32°F, make sure the unit is not running in defrost while balancing by waiting 10 minutes after
plugging the unit in.
Set the unit to high speed.
B
P
ALANCING
ROCEDURE
1.
Place the magnehelic gauge on a level surface and adjust it to zero.
2.
Connect tubing from gauge to EXHAUST airflow pressure taps (see diagram on unit door).
3.
Be sure to connect the tubes to their appropriate high/low fittings. If the gauge drops below
zero, reverse the tubing connections.
4.
Note the CFM value from balancing chart on the unit.
5.
Repeat steps 3 and 4, but to FRESH airflow pressure taps.
6.
Using the appropriate adjustable balancing damper, lower the highest value so it matches
the lowest value. A difference up to ±10 cfm is acceptable.
7.
Secure both dampers in place with a fastening screw (included in the hardware kit).
8.
Write the required airflow information on a label and stick it near the unit for future reference (date, maximum speed air flows, your
name, phone number and business address).

10. SERVICE PARTS

3
5
4
6
7
VL0050
2
8
10
9
1
18
17
16
15
14
VP0022
19
12
11
15
14
13

Publicité