For the Installer
7.2 E
C
LECTRICAL
ONNECTION TO
Always disconnect the unit before making any connections. Failure in disconnecting power could result in electrical
shock or damage of the wall control or electronic module inside the unit.
Never install more than one optional main wall control per unit. Make sure that the wires do not short-circuit
between themselves or by touching any other components on the wall control. Avoid poor wiring connections. To
reduce electrical interference (noise) potential, do not run wall control wiring next to control contactors or near
light dimming circuits, electrical motors, dwelling/building power or lighting wiring, or power distribution panel.
Use the terminal connector included in the installation kit to perform the
electrical connection for main and optional wall controls.
Make sure all wires are correctly inserted in their corresponding holes in
the terminal block. A wire is correctly inserted when its orange receptacle
is lower than another one without wire. On picture below, wire A is correctly
inserted, but wire B is not.
Use the chart below to verify compatibility with the optional controls before making any connection.
HRV CONSTRUCTO 1.5ES
HRV CONSTRUCTO 2.0ES
HRV SOLO 1.5ES
HRV SOLO 2.0ES
HRV NOVOFIT 1.5ES
HRV NOVOFIT 2.0ES
100H
200H
NOVO+ 100H
NOVO+ 200H
O
W
C
PTIONAL
ALL
ONTROL
B
A
VE0272
Main Controls
Deco-Touch
Lite-Touch Constructo
Constructo
Altitude
Deco-Touch
Lite-Touch Constructo
Altitude
Deco-Touch
Deco-Touch
Lite-Touch Bronze
Bronze
Platinum
Deco-Touch
WARNING
CAUTION
Once the wall control(s) connections have
been made, insert the terminal connector in the
electrical compartment.
If an optional main control is being installed, make
sure that the unit is set to OFF using the integrated
push-button.
Simple Touch Constructo
Constructo
12
T
ERMINAL
CONNECTOR
VD0278
Auxiliary Controls
Dehumidistat
20-minute lighted push button
60-minute crank timer
Dehumidistat
20/40/60-minute push-button timer
60-minute crank timer
20/40/60-minute push-button timer
60-minute crank timer
Dehumidistat
20-minute lighted push button
60-minute crank timer
20/40/60-minute push-button timer
60-minute crank timer