For the Installer
6.3 I
D
NSTALLING THE
UCTWORK AND THE REGISTERS
• Never install a stale air exhaust register in a closed room where a combustion device operates, such as a gas
furnace, a gas water heater or a fireplace.
• When performing duct connections, always use approved tools and materials. Respect all corresponding laws
and safety regulations. Please refer to your local building code.
6.3.1 F
D
S
ULLY
UCTED
YSTEM
Stale air exhaust ductwork:
•
Install registers in areas where contaminants are produced: Kitchen, bathrooms,
laundry room, etc.
•
Install registers on an interior wall, 6 to 12 inches (152 to 305 mm) away from the
ceiling OR install them in the ceiling.
•
Install the kitchen register at least 4 feet (1.2 m) away from the range.
Fresh air distribution ductwork:
•
Install registers in bedrooms, dining room, living room and basement.
•
Install registers either in the ceiling or high on the walls with the airflow directed
towards the ceiling.
•
If a register must be installed in the floor, direct the air flow up the wall.
6.3.2 E
D
S
XHAUST
UCTED
YSTEM
When performing duct connections to the furnace supply
duct, use metal ducts appropriately sized to support the
additional airflow produced by the unit.
Stale air exhaust ductwork:
•
Install registers in areas where contaminants are produced: Kitchen, bathrooms,
laundry room, etc.
•
Install registers on an interior wall, 6 to 12 inches (152 to 305 mm) away from the
ceiling OR install them in the ceiling.
•
Install the kitchen register at least 4 feet (1.2 m) away from the range.
Fresh air distribution ductwork:
•
Cut an opening into the furnace supply duct at least 18 inches (0.5 m) away from
the furnace.
•
Connect this opening to the fresh air distribution port of the unit (use metal ducts,
see illustration at right).
•
Make sure that the duct forms an elbow inside the furnace ductwork.
NOTE : For this type of installation, it is recommended, however, not essential, that the
furnace blower be synchronized with the unit.
6.3.3 E
D
S
XHAUST
UCTED
YSTEM
Stale air exhaust ductwork:
•
Install registers in areas where contaminants are produced: Kitchen, bathrooms,
laundry room, etc.
•
Install registers on an interior wall, 6 to 12 inches (152 to 305 mm) away from the
ceiling OR install them in the ceiling.
•
Install the kitchen register at least 4 feet (1.2 m) away from the range.
Fresh air distribution ductwork:
•
Cut an opening into the furnace return duct not less than 10 feet (3.1 m) away
from the furnace (A+B).
•
Connect this opening to the fresh air distribution port of the unit (see illustration
at right).
NOTE : For this type of installation, it is recommended, however, not essential, that the
furnace blower be synchronized with the unit.
- S
S
UPPLY
IDE
CAUTION
- R
S
ETURN
IDE
⚠
WARNING
VH0077
VH0130
VH0131
8
18" (0.5
)
M
MINIMUM
A
B
A + B =
AT LEAST
10' (3.1
)
M