English
WARNING
This unit must be serviced by trained and qualified
personnel only. Service by unqualified personnel may lead
to electric shock or burn.
Symptom
Unit is plugged in, but nothing
works.
Unit operates, but is not
circulating air inside cabinet.
Unit is leaking.
Unit is not producing any "hot
air" inside cabinet.
Unit is heating, but is not
producing
humidity
inside
cabinet.
Error Codes
The following error codes may appear on the CABINET
TEMPERATURE display to indicate an error in the operating
condition of the unit.
E1 = Air temperature sensor malfunctioning. Contact Authorized
Service Agent or Hatco for assistance.
E2 = Humidity temperature sensor malfunctioning. Contact
Authorized Service Agent or Hatco for assistance.
Form No. FSHC7WM-1119
Probable Cause
Unit not turned on.
No power to unit.
Power
cord
connections
disconnected.
Power cord is damaged.
Defective POWER ON/OFF (I/O) switch.
Defective digital temperature controller.
Blower motor defective.
Incorrect voltage supplied to blower motor.
The drain valve is not tight enough.
Safety high-limit is tripped or open.
Incorrect voltage supplied to heating element.
Blower motor not working.
Air heating element(s) defective.
Water reservoir is empty.
Humidity is set too low.
Water element defective.
Incorrect voltage supplied to water heating
element.
TROUBLESHOOTING GUIDE
ELECTRIC SHOCK HAZARD: Turn OFF power switch,
unplug power cord, and allow unit to cool before
performing any cleaning, adjustments, or maintenance.
Move POWER ON/OFF (I/O) switch to the ON (I) position.
Check electrical receptacle and verify that power supply
matches specifications on unit. If receptacle is not working,
check circuit breaker and reset, or plug unit into a different
known working receptacle.
are
loose
or
Contact Authorized Service Agent or Hatco for assistance.
Contact Authorized Service Agent or Hatco for assistance.
Contact Authorized Service Agent or Hatco for assistance.
Contact Authorized Service Agent or Hatco for assistance.
Contact Authorized Service Agent or Hatco for assistance.
Contact Authorized Service Agent or Hatco for assistance.
Tighten drain valve by pinching.
Contact Authorized Service Agent or Hatco for assistance.
Contact Authorized Service Agent or Hatco for assistance.
Contact Authorized Service Agent or Hatco for assistance.
Contact Authorized Service Agent or Hatco for assistance.
Fill water reservoir with clean water.
Increase humidity level. Refer to "Setting the Humidity Level"
in the OPERATION section.
Contact Authorized Service Agent or Hatco for assistance.
Contact Authorized Service Agent or Hatco for assistance.
Troubleshooting Questions?
If you continue to have problems resolving an issue, please
contact the nearest Authorized Hatco Service Agency or Hatco
for assistance. To locate the nearest Service Agency, log onto
the Hatco website at www.hatcocorp.com, select the Support
pull-down menu, and click on "Find A Service Agent"; or contact
the Hatco Parts and Service Team at:
Telephone: 800-558-0607 or 414-671-6350
e-mail:
support@hatcocorp.com
13
WARNING
Corrective Action